Page #162 background imageLoading...
Page #162 background image
5-76
Analog monitor output zero offset can be adjusted by parameters Cn027&Cn028 as below.
Parameter Name Default Unit Setting Range Control Mode
Cn027
Analog Monitor 1
Offset adjustment
4 x40mV -250~250 ALL
Cn028
Analog Monitor 2
Offset adjustment
4 x40mV -250~250 ALL
Analog Monitor
Output Voltage (V)
Adjusting Value for
Bias Voltage
Time
5-6-12 Factory Setting Parameter
This parameter can reset all parameter settings to default value (factory reset).
Parameter Name Setting Description
Control
Mode
0 Disabled
Cn029
Reset parameters
1 All parameters are reset to default values.
ALL
New setting will become effective after re-cycling the power.