Applications
1.
Set
the
left
and
right
TRIGGER
SOURCE
controls
to
EXT
and
EXT=Z,
respectively.
2.
Apply
a
signal
to
either
the
CH1
or
the
CH2
connector
and
set
the
VERTICAL
MODE
selector
to
display
the
channel
used.
3.
Apply
the
Z-modulation
signal
to
the
connector
labeled
EXT
INPUT
or
Z.
When
the
Z-modulation
and
the
vertical-input
signals
are
syn¬
chronized,
Z-modulation
is
seen
as
gaps
in
the
trace
at
the
modulation
frequency.
The
size
of
the
gap
depends
upon
the
mark-to-space
ratio
of
the
Z-moduiation
signal.
The
positive¬
going
portion
of
the
Z-modulation
signal
decreases
display
brightness.