Service
Information-T921/T92
2/T922R
solution
of
one
part
Kelite to
20
parts
water
.
If
these arenot
available,
petroleum
ether,
white kerosene,
or
a
solution
of
1%
Joy
detergent
and
99%
water
may
be
used
.
Recommended
circuit
coolants
are
dry
ice
and
isopropyl
alcohol
.
The
cam
switch
contacts are
designed
to
operate
without
lubrication
.
They
do
require
cleaning
periodically
to
remove
accumulations
of
dust
and
dirt
.
The
use
of
lubricants
or
cleaners
that
leave
a
residue,
increase
dust
attraction
and
should
be
avoided
.
Visual
Inspection
Inspect the
interior
occasionally
for
broken
connec-
tions,
improperly
seated
semiconductors,
damaged
or
improperly
installed circuit
boards, heat
damaged
com-
ponents,
etc
.
If
heat
damaged
components
arefound, care
mustbe
taken
to
find
the
cause
of
the excessive heat
and
measures
must
be
taken
to
prevent
recurrence
of
the
damage
.
Lubrication
Most
of
the
potentiometers
are
permanently
sealed
.
Both
the
cam-
and
lever-type
switches
are
installed
with
proper
lubrication
where
necessary
.
Therefore
periodic
lubrication
is
not
recommended
and
only
rarely
should
lubrication
even
be
necessary
.
Semiconductor
Checks
Periodic
checks
of
the
semiconductor
devices
in
this
instrument
are
not
recommended
.
The
best
check
of
semiconductorperformance
is
actual
operation
in
the
instrument
.
Re-adjustment
Re-adjust the
instrument
whenever
the
Performance
Check
indicates
the
instrument
is
not
meeting
specifications
.
The
Performance
Check
should
be
per-
formedon
a
regular
basis
;
for
example,
every
1000
hours
of
operation
or
every
six
months
.
If
you
perform
preventive
maintenance
on
a
regular
basis,
you
should
correct
most
problems
before
your
instrument
breaks
down
.
Occasionally,
you
may
have
to
troubleshoot
.
In
addition
tothe
following
information,
you
may
find
information
in
the
Circuit
Description
and
Diagrams
section
useful
.
5-2
TROUBLESHOOTING
Troubleshooting
Aids
Troubleshooting
Chart
.
Use
the troubleshooting
chart
(Fig
.
5-1) to
locate
problem
areas
.
Diagrams
.
Complete
circuit
diagrams
are
located
on
thefoldout
pages
in
the
Circuit
Description
and
Diagrams
section
.
The
componentnumber
and
electrical
value
of
each
component
in
the
instrument are
shown
on
the
diagrams
(see
the
first
page
of
the
Diagrams
section
for
the
definitions
of
the
reference
designators
used
to
identify
components)
.
Each main
circuit
is
assigned
a
series of
component
numbers
to
assist
in
identifying
their
circuit
location
.
Important
voltages
andwaveforms
are
also
shown
on the
diagrams
.
Also
a
heavy
line
encloses
the
portion
of
the
circuit
mounted
on
a
circuit
board
.
Color
Codes
.
The
resistors
used
in
this
instrument are
either
brown
composition
or
precision
metal-film
resistors
.
The
resistors
are
color-coded
with the
EIA
color-
code
.
(Some
metal-film
resistors
may
have
the value
printed
on
the
body
.)
Refer
to
Fig
.
5-2
.
For
the
values
of
the
thick
film
resistors,
refer
to
the
Parts
List
.
The
capacitance
values
of
common
disc
and
some
small
electrolytic
capacitors
are
markedon
the
side
of
the
component
body
.
The
white
ceramic
capacitors
are
color-
coded,
using
a
modified
EIA
code
.
(See
Fig
.
5-2)
.
The
cathode
end
of
each
glass-encased
diode
is
indicated
by
a
stripe,
a
series
of
stripes,
or
a
dot
.
Semiconductor
Lead
Configuration
.
Fig
.
5-3
shows
the
lead
configuration
of
the
semiconductor
devices
used
in
this
instrument
.
Troubleshooting
Equipment
Multi-connector
Holders
.
The
multi-connector
holder
is
keyed
with
two
triangles,
one
on
the
holder
andone
on
the
circuit
board
.
When
a
connection
is
made
perpen-
dicular
to
a
circuit
board
surface,
the
orientation
of
the
triangle
and
the
slot
numbers
on
the
connector
holder are
determined
by
the
direction
of
the
nomenclature
marking
(see
Fig
.
5-4)
.
The
following
equipment
is
useful
for
troubleshooting
.
1
.
Semiconductor
Tester
Description
:
Dynamic-type
tester
.
Must
be
capable
.
of
measuring
reverse
breakdown
voltages
of at
least
400
V
.
REV
.
A
JUN
1976

Questions and Answers: