This
manual
includes
instructions for
the
T921,
T922
and
T922R
portable
oscilloscopes
.
The
T922
is
a
15
MHz,
dual
trace,
oscilloscope
and
the
T921
is
a 15
MHz,
single
trace
oscilloscope
.
The
Vertical
Amplifier,
either
single
trace
or
dual
trace,
provides
calibrated
deflection
factors
from
2
mV
to 10
V/div
.
The
TimeBase
provides
stable
triggering
over
the
full
bandwidth
of
the
Vertical
Amplifier(s)
and
provides
calibrated
sweep
rates
from
0
.5
s/div
to
0
.2
Ns/div
.
A
variable
X1
to
X10
magnifier
extends
the
maximum
sweep
rate
to
20
ns/div
.
The
T992R
is
a
rackmount
verison
of
the
T922
os-
cilloscope
which
takes
5-1/4
inches
of
rack
space
.
Characterist
ic
Probe
Adjust
Output
Voltage
(0°Cto
+40°
C)
Repetition
Rate
Z-Axis Input
Sensitivity
Signal
Polarity
T921
and
T922
T922R
REV
.
C
APR
1977
PerformanceRequirement
A
.
DISPLAY
Approximately
0
.5
V
.
Approximately
1
kHz
.
5
volt
signal
causes
a
noticeable
decrease
in
intensity
.
Positive
going
from
ground
.
Either polarity of
signal
can
be
applied,
depending
upon
internal
jumper
connections
.
SPECIFICATIONS
TABLE
1-1
Electrical
Features
added
to
the
rackmount
version
include
:
single
sweep
;
rear
panel
outputs
for
Sweep
Gate,
Sweep
Ramp,
and
Vertical
Signal
;
internally
selectable
Z
Axis
polarity
;
user
selection
of
the
CHOP
or
ALT
dual
trace
modes
;
and
switch-selectable
front-panel
or
rear-panel
inputs for
CH
1,
CH
2,
and
EXT
TRIG
signals
.
The
following
instrument
specifications
apply
over an
ambient temperature
range
of
0°C
to
+45°C
unless
otherwise
specified
.
The
Adjustment
Procedure
in
Section
4,
when
performed
completely,
allows
the
T921/T922/
T922R
to
meet
the
electrical
specifications
listed
in
Table
1-1
.
Characteristic
Line
Frequency
1
50
to
60 Hz
.
Maximum
Power
Consumption
CRT
Display
Display
Area
Trace
Rotation
Range
Standard
Phosphor
Nominal
Accel-
erating
Potential
Section
1-T921/T922/T922R
36 W,
0
.35
A
at
60 Hz,
120
V
line
.
8 x 10
cm
.
Adequate
to
align
trace
with
horizontal
center
line
.
P31
.
PerformanceRequirement
12,400
V
.
B
.
VERTICAL
AMPLIFIER
Usable
Frequency
Range
Dc
to
5
MHz
.
Deflection
Factor
Maximum
Input
30
V
(dc
+
peak
ac)
30
V
p-p
at
Range
2
mV/div
to
10
V/div
;12steps
in
a
1-
Voltage
1
kHz
or
less
.
2-5
sequence
.
Input
Impedance
Approximately
10
kit
.
Accuracy
Power
Source (T922R
120
V-240
V
Range
and
Line
Voltage
HI-LO
adjustments
are not
exter-
+20°
C
to
Within
3%
.
Ranges
(ac,rms)
nally
accessible)
.
+30°
C
120
V
Range HI-108
to
132
V
.
O'
C
to
+45
1
C
Within
4%
.
LO-90
to
110
V
.
Uncalibrated
Continuously
variable
between
240
V
Range
HI-216
to
250
V
.
(VAR)
Range
settings
.
Extends
deflection
factor
LO-198
to
242
V
.
to at
least
25
V/div
(at