37
Declaration of Performance
TT20-CPR-2016-Version1
Product:
Product type/application: Room heater burning solid fuel without hot water supply
Type: TT20: S01-600/601, TT20R: S01-602/603, TT20SA: S01-626,
TT20S: S01-618/619, TT20RS: S01-620/621, TT20BAZIC / R: S01-606/608
Fuel: Wood
Productions no. Please see nameplate on the back of the oven
Manufacturer:
TermaTech A/S E-mail: info@termatech.com
Gunnar Clausens Vej 36 Web: www.termatech.com
8260 Viby J Tel.: +45 8742 0035
Denmark
Certification and requirements:
AVCP system: System 3
European standard: DS/DIN/EN 13240:2001 + A2:2004/2007
Certification: Rhein-Ruhr Feuerstätten Prüfstelle GmbH, notified body no. 1625, has
performed determination of the product type and declared performance on
the basis of type testing and issued test report no. 40 11 2613. Teknologisk
Institut, notified body no. 1235, has performed determination of the product
type and declared performance on the basis of type testing and issued test
report no. 300-ELAB-1520-SIK-Rev-1.
Declared performance:
The undersigned is responsible for the manufacturing and conformity with the declared performance.
1.6.2016 Søren Toft______________________________
Essential characteristics
Performance Harmonised technical
specification
DS/DIN/EN 13240:2001
+ A2:2004/2007
Distance to combustible materials
Rear: min. 150 mm
Sides: min. 350 mm
Other safety distances – please see User
and mounting manual
Emission of combustion products CO = 0,08 %
NOx = 125 mg/m³
OGC = 107 mgC/Nmᶟ
Risk of burning fuel falling out Passed
Surface temperature Passed
Clean ability Passed
Mechanical strength Passed
Emission of hazardous materials Passed
Flue gas temperature 273° Celsius
Output 5,0 KW
Energy efficiency 83,4 %