Specifications
Line Voltage: 115/230 V a.c. 50/60 Hz (switchable),
130 VA (100W)
Current Draw (no load): 0.07A @ 115V, 60 Hz,
0.09A @ 230V, 50 Hz
Current Draw (maximum load): 0.76A @ 115V, 60 Hz,
0.41A @ 230V, 50 Hz
Secondary Voltage Output: 24 V a.c.,50/60 H,
3.0A (72 VA)
Maximum Load Per Station Output:
0.75A (18 VA)
Maximum Load Per Pump/Master Valve Output:
0.75A (18 VA)
Maximum Total Load: 3.0A (72 VA)
Hardware Features
Plastic: 44 1/2" x 16" x 15" (113.0 cm x 40.6 cm x 38.1 cm)
Top Locking Cover
Fuses and Circuit Breakers
Power Supply:
1.5A On/Off Switch/Circuit Breaker – Main Power Input
3.2A Fuse (Slow-Blow) – Field Output
4.0A Fuse (Slow Blow) – Station Output Module
4.0A Circuit Breaker – Control Functions
Pump/Common & Communication Surge Protection Module:
0.5A Fuse
Table 2 – Hand-held Radio Command Codes (continued)
Command Code Operation Description
7525 Turns on individual stations as switches for a time given in minutes; i.e., does not
simultaneously energize the pump in this command string, the run time is entered first, followed by
the station numbers; e.g., 7525 25 05 42 turns on stations 5 and 45 for 25 minutes without
energizing the pump.
7526 Turns on individual stations as switches for the time given in hours, minutes and seconds.
In this command string, the run time is entered first, followed by the station numbers; e.g., 7526 02
30 45 25 26 27 turns on stations 25, 26 and 27 for 2 hours, 30 minutes and 45 seconds.
7540 Turns off all stations (this satellite only).
7543
Disables all stations in all satellites (rain shutdown). Note: Satellite address code 256 is used
with 7543 and 7544 command codes. The stations will not respond to any further commands until
enabled.
7544 Enables operation of all stations in all satellites. See Note above.
7546 Sequentially syringes all stations for a set length of time; e.g., 7546 turns on all stations for the
predetermined number of 30 second intervals as defined in the syringe time.
7800 Disable the remote relay on the frequency decoder module.
7801 Enable the remote relay on the frequency decoder module.
7810 Turns off the remote relay on the decoder module. Resumes function to the satellite unit.
7811 Turns on the remote relay on the decoder module. Disables function to the satellite unit.
8000 Disables pump start.
8001 Enables pump start to be assigned to a station; e.g., 8001 48 assigns pump start to station 48.
8003 00 Disables operation and turns off all stations in the satellite with sequential shutdown.
8003 01 Enables operation of all stations in the satellite.
8004 Changes the password; e.g., 8004 7531 6108 will change the factory default password (7531) to
6108.
8006 01 Sets the syringe time in 30-second intervals; e.g., 8006 01 0100 (without a password) or 8006
pppp 01 0100 (with a password) sets the syringe time to 100 intervals (50 minutes). The number of
intervals must be given as four digits with leading zeros but can be no greater than 0255.
8006 02 Sets the time-out limit in 30-minute intervals. This must be specified using four digits with
leading zeros and no greater value than 0255; e.g., 8006 02 0060 (without a password) or 8006
pppp 02 0060 (with a password) sets the time-out limit to 30 hours.
8006 03 Enables/disables the password. Use 8007 03 01 to enable password protection or 8007 03 00 to
cancel password protection.
8008 Configures stations as switches. Stations can be specified individually and in combination with a
range of stations; e.g., 8008 01 12 50 – 60 configures stations 1, 12 and 50 through 60 as
switches. Note: Only a single dash is used when entering a range of stations.
8009 Configures stations for irrigation. Stations can be specified individually and in combination with
a range of stations; e.g., 8009 01 20 45 – 48 configures stations 1, 20 and 45 through 48 for
irrigation.
8011 Resets EPROM to factory defaults.