E6581172
1
1. Introduction
Thank you for purchasing the Toshiba industrial inverter “TOSVERT VF-A7/P7”.
This manual functionally describes the light-load high-speed operation of our "TOSVERT VF-A7/P7" for
industrial use.
2. Function
This parameter provides a function of more raising the speed of motor during light load to improve the
operating efficiency of machine.
It is effectively applicable to elevators and conveyers under constant-torque loads with alternated light and
heavy loads.
3. Related parameter
List of parameters for adjusting light-load high-speed operation
Vector control
Title
Communi
cation No
Function
Adjustment
range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
 0330 Light-load high-speed operation 010*1 0 Disabled /●−
 0331
Light-load high-speed operation
switching lower limit frequency
30.0 [Hz] 0.01/0.01 40.0 Enabled /●−
 0332
Light-load high-speed operation
load waiting time
0.010.0 [s] 0.1/0.1 1.0 Enabled /●−
 0333
Light-load high-speed operation
load detection time
0.010.0 [s] 0.1/0.1 1.0 Enabled /●−
 0334
Light-load high-speed operation
heavy load detection time
0.010.0 [s] 0.1/0.1 2.0 Enabled /●−
 0335
Switching load torque current
during forward run
0250 [%] 1 50 Enabled /●−
 0336
Heavy load torque during
acceleration in forward direction
0250 [%] 1 150 Enabled /●−
 0337
Heavy load torque during fixed
speed in forward direction
0250 [%] 1 100 Enabled /●−
 0338
Switching load torque current
during reverse run
0250 [%] 1 50 Enabled /●−
 0339
Heavy load torque during
acceleration in reverse direction
0250 [%] 1 150 Enabled /●−
 0340
Heavy load torque during fixed
speed in reverse direction
0250 [%] 1 100 Enabled /●−
 0341
Automatic light-load high-speed
operation frequency
30.0 [Hz] 0.01/0.01 80.0 Enabled /●−
 0342 Light-load detection mode*2 0255 1/1 0 Disabled /●−
Sensorless vector/vector with sensor (: Valid,−: Invalid)
*1F330= 0: Disabled light-load high-speed operation
1: User interface (torque current)
2: Continuous automatic mode (torque current)
3: Continuous preset-speed mode (torque current)
4: Enabled-terminal effective automatic mode (torque current)
5: Enabled-terminal effective preset-speed mode (torque current)
6: User interface (torque)
  *2
7: Continuous automatic mode (torque)  *2
8: Continuous preset-speed mode (torque)  *2
9: Enabled-terminal effective automatic mode (torque)  *2
10: Enabled-terminal effective preset-speed mode (torque)  *2
*2 These are not before CPU version V312.

Other manuals for Toshiba TOSVERT VF-A7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-A7 and is the answer not in the manual?

Toshiba TOSVERT VF-A7 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-A7
CategoryInverter
LanguageEnglish

Related product manuals