E6581911
- 1 -
Introduction
Thank you for purchasing TOSVERT VF-S15 series Inverter.
Before using CANopen
®
communication function, carefully read this function manual in order to completely and
correctly utilize its excellent performance.
After reading this function manual, please keep it handy for future reference.
For details of its general handling, see an instruction manual attached with the option unit.
TOSVERT VF-S15 Instruction Manual ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ E6581611
TOSVERT VF-S15 Communications Function Instruction Manual ・・・・・・・・・・・ E6581913
VF-S15 Option Adapter Instruction Manual ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ E6581838
EDS file
Please contact your Toshiba distributor on EDS file.
* CANopen
®
and CiA are a registered trademark of CAN in Automation.
Handling in general
Danger
Mandatory
Do not connect or disconnect a network cable while the Inverter power is on.
It may lead to electric shocks or fire.
See the instruction manual attached with the option unit for cautions the handling.
Otherwise, it may lead to electric shocks, fire, injuries or damage to product.
Network control
Danger
Prohibited
Do not send the value out of the valid range to network variables.
Otherwise, the motor may suddenly start/stop and that may result in injuries.
Mandatory
Use an additional safety device with your system to prevent a serious accident due to the
network malfunctions. Usage without an additional safety device may cause an accident.
Warning
Mandatory
Set up “Communication error trip function (see below)” to stop the Inverter when the
network is deactivated by an unusual event such as tripping, an operating error, power
outage, failure, etc.
- Communication error trip time, Operation at communication error
(Refer to “6.4 Communication disconnection detection function” for details)
Deactivated the Inverter may cause an accident, if the “Communication error trip
function” is not properly set up.
Make sure that the operation signals are STOP before resetting Inverter’s fault. The
motor may suddenly start and that may result in injuries.
Notes on operation
Notes
When the control power is shut off by the instantaneous power failure, communication
will be unavailable for a while.
The Life of EEPROM is approximately 100,000 times. Avoid writing a command more
than 100,000 times to the same parameter of the Inverter and the communication board.

Table of Contents

Other manuals for Toshiba TOSVERT VF-S15 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-S15 series and is the answer not in the manual?

Toshiba TOSVERT VF-S15 series Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-S15 series
CategoryInverter
LanguageEnglish

Related product manuals