Product Specification
MODEL 4WCC4024 4WCC4030 4WCC4036 4WCC4042 4WCC4048 4WCC4060
RATED Volts/PH/Hz 208–230/1/60
Performance Cooling BTUH
(a)
23800 29800 35200 43000 47000 57000
Indoor Airflow (CFM)
770 985 1105 1355 1590 1835
Power Input (KW)
2.09
2.55 3.03 3.54 4.10 4.85
EER2/SEER2 (BTU/Watt-Hr.)
(b)
11.0 / 13.4
Sound Power Rating [dB(A)]
(c)
66.4 70.0 69.4 71.5 72.5 77.3
PERFORMANCE HEATING 208–230/1/60
(High Temp.) BTUH
23200 28600 34400 39000 45000 55000
Power Input (KW)
1.95
2.31 2.93 3.43 3.94 4.71
(Low Temp.) BTUH
14700 17200 22000 23400 26200 35400
Power Input (KW) 1.78 2.16 2.76 3.15 3.61 4.34
HSPF2 (BTUH/Watt-Hr)
7.0
POWER CONN. — V/Ph/Hz 208–230/1/60
Min. Brch. Cir. Ampacity
(d)
LOCATED ON UNIT NAMEPLATE
Fuse Size — Max. (amps)
LOCATED ON UNIT NAMEPLATE
Fuse Size — Recmd. (amps)
LOCATED ON UNIT NAMEPLATE
COMPRESSOR SCROLL
VOLTS/PH/HZ 208–230/1/60
R.L. Amps — L.R. Amps
LOCATED ON UNIT NAMEPLATE
OUTDOOR COIL — TYPE SPINE FIN
Rows/F.P.I 2 / 24
Face Area (sq. ft.)
13.32 13.32 15.49 20.54 20.54 22.90
Tube Size (in.)
3/8
Refrigerant Control
EXPANSION VALVE
INDOOR COIL — TYPE PLATE FIN
Rows/F.P.I 3 / 15 3/15 4/15 4/15 3/15 3/15 4/15
Face Area (sq. ft.)
3.5 5.0
Tube Size (in.)
3/8
Refrigeration Control
EXPANSION VALVE
Drain Conn. Size (in.)
3/4" FEMALE NPT
OUTDOOR FAN — TYPE SWEPT
DIA. (IN.)
23.4 28.3
DRIVE/NO. SPEEDS DIRECT / 1
CFM @ 0.0 in. w.g.
(e)
2550 3270 3250 4400 4400 5500
Motor — HP/R.P.M 1/12 /850 1/6/842 1/5/855 1/4/798 1/4 /825 1/3/825
Volts/Ph/Hz 208–230/1/60
F.L. Amps/L.R Amps
LOCATED ON UNIT NAMEPLATE
INDOOR FAN — TYPE Constant Torque ECM
Dia. x Width (in.)
10.62 x 10.68 10.62 x 10.62 11.87 x 10.68
Drive/No. Speeds
DIRECT / 4
CFM @ 0.0 in. w.g.
(f)
SEE FAN PERFORMANCE TABLE
Motor — HP / R.P.M. 1/2/1050 1/2/1050 1/2/1050 3/4/1050 3/4/1050 1/1050
Volts/Ph/Hz 208–230/1/60
F.L. Amps
LOCATED ON UNIT NAMEPLATE
FILTER / FURNISHED
NO
Type Recommended
THROWAWAY
Recmd. Face Area (sq. ft)
(g)
2.7 4 5.3
REFRIGERANT R-410A
Charge (lbs.)
LOCATED ON UNIT NAMEPLATE
Subcooling
16°
14° 11° 9° 8° 6°
(a)
Rated in accordance with AHRI Standard 210/240.
(b)
Rated in accordance with D.O.E. test procedure.
(c)
Sound Power values are not adjusted for AHRI 270–95 tonal corrections.
(d)
Calculated in accordance with currently prevailing Nat’l Electrical Code.
(e)
Standard Air — Dry Coil — Outdoor.
(f)
Standard Air — Dry Coil — Indoor
(g)
Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per
manufacturer’s recommendation with a clean resistance of 0.05” W.C.