S8XB-SVX001-1C-EN
Troubleshooting
The following pages include troubleshoong flowcharts in reference for
the 1 Stage S8B1, S8X1 and 2 Stage S8X2 families of furnaces only.
The informaon contained is for reference only and does not cover all
scenarios or problems that may be encountered.
ONLY qualified technicians should aempt to install, troubleshoot, or
repair this appliance.
Failure to follow all cauons and /or warnings could result in personal or
property damage, including death.
Troubleshoong Flowchart Index
IFC Component Layout
Error Codes
E01 – Internal failure
E2.1 – Retries Exceeded (flame never sensed)
E2.2 – Recycles Exceeded (loss of flame a!er being sensed)
E2.3 – 1
st
Stage Gas Valve energized when it should not be (10 mes)
E3.1 – Shorted Pressure Switch, 1
st
Stage
E3.2 – Open Pressure Switch, 1
st
Stage
E3.3 – Shorted Pressure Switch, 2
nd
Stage
E3.4 – Open Pressure Switch, 2
nd
Stage
E04 – Open Thermal Limit
E05 – Flame Detected , should not be present
E6.1 – Reversed Polarity (High Voltage)
E6.2 – Faulty Ground
E6.3 – Igniter Circuit
E07 – 1
st
Stage Gas Valve (MVL) energized when it should not be
E08 – Flame Current Low, operaon allowed
E11 – See troubleshoong Instrucons
E12 – Open fuse
Status Codes
Menu Opons

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane S8B1A040M3PSCA/C and is the answer not in the manual?

Trane S8B1A040M3PSCA/C Specifications

General IconGeneral
BrandTrane
ModelS8B1A040M3PSCA/C
CategoryFurnace
LanguageEnglish