18-CE16D1-1B-EN
39
Electrical Connections
Make wiring connections to the unit as indicated on enclosed wiring diagram. As with all gas appliances using electrical power, this furnace shall
be connected into a permanently live electric circuit. It is recommended that furnace be provided with a separate "circuit protection device"
electric circuit. The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the National
Electrical Code, ANSI/NFPA 70 , if an external electrical source is utilized. The integrated furnace control is polarity sensitive. The hot leg
of the 120V power supply must be connected to the black power lead as indicated on the wiring diagram.
Refer to the SERVICE FACTS literature and unit wiring diagram attached to furnace.
Field Wiring
O
Y2
Y1 Y1
B B
W1W1
GG
RR
Y1
Two Stage
Thermostat
Furnace
Outdoor Unit
(No Transformer)
O
R
X2
Y2
NOTES:
1) HP = Wiring used for Heat Pump systems.
2) Y1 and/or Y2 must connect from the thermostat to the IFC
for proper airflow.
3) A/TCONT824 thermostats do not require the use of X2.
4) Y2 not available for S8B1.
HP
HP
HP
FIELD WIRING DIAGRAM FOR S8B1 / S8X1 SINGLE STAGE
HEATING THERMOSTAT, ONE / TWO STAGE AC OR HEAT PUMP
Y2
B
O
Y2
Y1 Y1
B B
W2W2
W1W1
GG
RR
O
Y1
Two Stage
Thermostat
Furnace
Outdoor Unit
(No Transformer)
O
R
X2
Y2
NOTES:
1) HP = Wiring used for Heat Pump systems.
2) Y1 and/or Y2 must connect from the thermostat to the IFC
for proper airflow.
3) Remove Y1-O jumper for HP systems. O terminal must be
connected as shown for gas heating operation during defrost.
4) If the thermostat does not have W2, or there are not enough
conductors jumper W1 to W2 at the IFC.
5) A/TCONT824 thermostats do not require the use of X2.
HP
HP
HP
HP
FIELD WIRING DIAGRAM FOR S8X2 TWO STAGE
HEATING THERMOSTAT, ONE / TWO STAGE AC OR HEAT PUMP
Y2
B
FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn

Other manuals for Trane S8B1B080M4PSBA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane S8B1B080M4PSBA and is the answer not in the manual?

Trane S8B1B080M4PSBA Specifications

General IconGeneral
BrandTrane
ModelS8B1B080M4PSBA
CategoryFurnace
LanguageEnglish

Related product manuals