54
S8V2-SVX001-1A-EN
Run Test Mode
S8V2-C
Run Test Mode:
To enter Run Test Mode, scroll to
u
si
ng t
h
e Men
u
k
e
y, t
h
en p
ush
t
h
e o
p
!o
n
k
e
y. T
h
e L
E
D
w
i
ll
ash
t
hre
e
!mes, then begin the test.
To exit the test mode, momentarily push the Menu key, cycle power to the furnace, or make a valid thermostat
call for capacity or fan.
Sequence of Run Test Mode
-Turns the inducer on in 1
st
stage for 30 seconds
Turns on the inducer on 2
nd
stage for 30 seconds
Turns the igniter on for 10 seconds
Turns the circula!ng blower on 1 stage compressor speed for 10 seconds
Turns the circula!ng blower on 2 stage compressor speed for 10 seconds
Turns the circula!ng blower on 1
st
stage gas heat speed for 10 seconds
Turns on the circula!ng blower on 2
nd
stage gas heat speed for 10 seconds
The above sequence will repeat two more !mes unless the Run Test Mode is exited, see above.
Important: The Run Test Mode does not test fire the furnace or bring the outdoor unit on. It is designed to allow
the technician to observe each mode to ensure the IFC, inducer, igniter and circula!ng blower are performing as
intended.
nd
st
Ht1 ARF
Ht2 ARF
CL1 ARF
CL2 ARF
HP1 ARF
HP2 ARF
COF ARF
DFT ARF
System Status Menu
Example
800 CFM
080
Example
1 Stage Pressure
Switch Error
1dL
IdL = Idle, no demand for cooling, heating, or fan
Ht1 = Demand for 1 stage gas heat
Ht2 = Demand for 2 gas heat
CL1 = Demand for 1 stage cooling
CL2 = Demand for 2 stage cooling
HP1 = Demand for 1 stage heat pump
HP2 = Demand for 2 stage heat pump
COf = Demand for continuous fan
dFt = Demand for outdoor unit defrost, furnace running
in gas heat mode
ARF 080 = Calculated airflow is 800 cfm
Note:
1. The status will alternate between the system mode and
the airflow request every 2 seconds.
3. If an error occurs, an E*.* will alternately flash with the
system mode and airflow request. See first example.
3. Multiply the value shown by 10 for actual airflow.
S8V2-C 24V
e3.1
130
080
080
140
140
070
140
nd
nd
nd
st
st
st
st
IInntteeggrraatteedd FFuurrnnaaccee CCoonnttrrooll MMeennuu

Questions and Answers: