Integrated Furnace Control Display Codes
Menu Options
ORN
Orientation
err
Active Alarm Menu
L6F
Last 6 Faults (To clear – Hold Option button down for 5 seconds after entering the L6F menu)
Cr
Code Release Number
MNR
Model Number Recovery
C0d
Cooling Off Delay (Seconds)
ODE
Outdoor Tonnage
0du
Outdoor Unit Type (Single / Two Stage)
C0f
Blower Constant Fan Airflow Multiplier %
CPC
Cooling (CFM/Ton)
CPH
Heat Pump Heating (CFM/Ton)
Xod
Heat Off Delay (Seconds)
!sd
Inter-Stage Delay (Seconds)
gXC
Gas Heating CFM (Airflow x10)
SAE
Supply Air Temperature
RAE
Return Air Temperature
RSP
Return Static Pressure
run
Run Test Mode
Error Codes
Alarm Error Code
Alarm Explanation
e0!
Loss of the IRQ or other internal IFC failures
e2.!
Retries exceeded (Flame never sensed, one hour lockout after 7 times)
e2.2
Recycles exceeded (Flame sensed then lost, one hour lockout after 10 times)
e2.3
1st stage gas valve not energized when it should be (10 times)
e3.!
Shorted pressure switch, 1st stage
e3.2
Open pressure switch, 1st stage
e3.3
Shorted pressure switch, 2nd stage
e3.4
Open pressure switch, 2nd stage
e04
Open high limit switch
e4.1
Open reverse air-flow limit switch
e4.2
Open roll-out limit switch
e05
Flame detected when it should not be present
e6.1
Voltage reversed polarity
e6.2
Bad grounding
e6.3
(1) Igniter open or igniter relay failure on IFC
(2) Igniter relay failure on IFC
e7.!
1st stage gas valve energized without request