Unit will not exit TRANE mode’ if user changes any of the following:
swing button, multi room or night latch button.
The indication of TRANE mode is button with red back light and the remaining buttons with light
OFF. The back light will go OFF after 20 seconds from last operation of remote controller.
2.4.2.2. Cool Mode
Figure - 8
COOL
DRY
FAN
e
1 2 3
Display
Press MODE to select cool mode, see ‘COOL shown on display (Refer Figure - 8).
Press to set fan speed (if required)
Press or to increase or decrease set temp. Set temperature range is 17°C - 30°C.
This is normal mode of cooling. User can set room temperature and AC will run to
attain the set temperature.
Temperature can be set based on energy consumption, Refer below table
Zone 1 - Red Uneconomical
Zone 2 - Yellow Higher energy consumption
Zone 3 - Light green Economical
Zone 4 - Dark green Lower energy consumption
2.4.2.3. Dry Mode
Press MODE to select dry mode, see ‘DRY’ shown on display
(Refer Figure - 10).
In dry mode default set temperature is 25°C.
Set temperature and fan speed cannot be changed.
Unit will operate at low fan speed for maximum moisture removal.
In high humidity conditions, user can select dry mode.
2.4.2.4. Fan Mode
Press MODE to select fan mode, see ‘FAN’ shown on display.
Set point temperature cannot be adjustable.
Fan speed can be adjustable.
2.4.2.5. Sleep Mode
Press to activate sleep mode operation.
The ‘set’ temperature will automatically increase by 1°C for each
hour for four hours.
After 4 hours unit will stay at latest temperature. E.g., if the
set temperature is 24°C and sleep mode is started. After rst hour
set temperature will increase to 25°C and at the end of fourth
hour set temperature will be at 28°C. The unit will stay at 28°C.
Press again to disable sleep mode.
Set point temperature and fan speed can be adjustable.
6.
7.
1.
2.
3.
1.
1.
1.
e
Figure - 9
1
2
3
4
e
Figure - 9
1
2
3
4
e
Display
Figure - 10
1
e
Display
Figure - 10
1
1
e
Display
Figure - 11
1
e
Display
Figure - 11
1
Display
Figure - 12
e
1
Display
Figure - 12
e

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane SPLIT AC and is the answer not in the manual?

Trane SPLIT AC Specifications

General IconGeneral
BrandTrane
ModelSPLIT AC
CategoryAir Conditioner
LanguageEnglish

Related product manuals