18-GF75D1-1C-EN
3
WWAARRNNIINNGG
SSAAFFEETTYY HHAAZZAARRDD!!
CChhiillddrreenn sshhoouulldd bbee ssuuppeerrvviisseedd ttoo eennssuurree tthhaatt tthheeyy
ddoo nnoott ppllaayy wwiitthh tthhee aapppplliiaannccee..
WWAARRNNIINNGG
WWAARRNNIINNGG!!
TThhiiss pprroodduucctt ccaann eexxppoossee yyoouu ttoo cchheemmiiccaallss
iinncclluuddiinngg lleeaadd,, wwhhiicchh aarree kknnoowwnn ttoo tthhee SSttaattee ooff
CCaalliiffoorrnniiaa ttoo ccaauussee ccaanncceerr aanndd bbiirrtthh ddeeffeeccttss oorr
ootthheerr rreepprroodduuccttiivvee hhaarrmm.. FFoorr mmoorree iinnffoorrmmaattiioonn ggoo
ttoo wwwwww..PP6655WWaarrnniinnggss..ccaa..ggoovv..
IImmppoorrttaanntt:: Installation of this unit shall be made in
accordance with the National Electric Code,
NFPA No. 90A and 90B, and any other local
codes or utilities requirements.
IImmppoorrttaanntt:: Air handlers do not require repositioning of
the coil or drain pan for upflow or
horizontal left applications. See the
downflow and horizontal right installation
sections for application instructions.
NNoottee:: Air handlers have been evaluated in accordance
with the Code of Federal Regulations, Chapter
XX, Part 3280 or the equivalent. “SUITABLE FOR
MOBILE HOME USE.”
NNoottee:: Condensation may occur on the surface of the air
handler when installed in an unconditioned
space. When units are installed in unconditioned
spaces, verify that all electrical and refrigerant
line penetrations on the air handler are sealed
completely.
NNoottee:: The manufacturer recommends installing ONLY
A.H.R.I approved, matched indoor and outdoor
systems. Some of the benefits of installing
approved matched indoor and outdoor split
systems are maximum efficiency, optimum
performance, and the best overall system
reliability.
Features
Table 1. Standard Features
• MULTI-POSITION UPFLOW, DOWNFLOW, HORIZONTAL LEFT
AND HORIZONTAL RIGHT
• PAINTED FINISH ON GALVANIZED STEEL EXTERIOR WITH
FULLY INSULATED CABINET THAT MEETS R4.2 VALUE
• STURDY POLYCARBONATE DRAIN PANS
– The TEM air handler has factory installed drain pans and
is shipped for upflow and horizontal left applications
• 208/230 VAC OPERATION
• MULTI-SPEED DIRECT DRIVE BLOWER.
• FACTORY INSTALLED R-410A THERMAL EXPANSION VALVE
• ALL ALUMINUM COIL
• BOTTOM RETURN
• MEETS THE MINIMUM LEAKAGE REQUIREMENTS FOR THE
FLORIDA AND CALIFORNIA BUILDING CODES
Table 2. Optional Accessories
• 4,5,8,10,15, 20 and 25 KW SINGLE PHASE ELECTRIC
HEATERS
– Circuit breakers available on all single phase 4, 5, 8, 10,
15, 20 and 25 KW heaters
– Lug terminals available on all single phase 4, 5, 8, and
10 KW heaters
• 10 and 15 KW THREE PHASE ELECTRIC HEATERS
– Heaters available with lug terminals
• SINGLE POINT POWER ENTRY KIT (for 15 and 20 KW
Heaters)
• SUPPLY DUCT FLANGE KIT
• DOWNFLOW SUB-BASE KITS - TAYBASE185, TAYBASE235
• R-22 CONVERSION KITS — BAYATXV1836B,
BAYATXV4248B, BAYATXV6161B
• SLIM FIT FILTER BOX KIT — BAYSF1185AAA,
BAYSF1235AAA
SSAAFFEETTYY SSEECCTTIIOONN