6 UHM-DHM-SF-1H
Service Facts
USER INTERFACE MENU
Power Up
== WAIT ==
A/TCONT900 Variable Speed
Standy Screen System Status Setup Options [ ] = Current Setting
MODEL NUMBER CMFRT CNT MODE
SERIAL NUMBER COMM [COMM] 24VAC
* Unit specific
COOLING CFM 2
COOLING CFM A/TUHMB060 3T [3T] 1.5T 2T 2.5T
* A/TUHMB080 3T [3T] 3.5T 2T 2.5T
A/TUHMC100 4T [4T] 2.5T 3T 3.5T
CFM PER TON CFM PER TON A/TUHMD120 5T [5T] 3.5T 4T
400 [ 400 ] 430 450 290 310 330 350 370 A/TDHMB060 3T [3T] 1.5T 2T 2.5T
A/TDHMB080 3T [3T] 3.5T 2T 2.5T
HEAT CFM HEAT CFM A/TDHMC100 4T [4T] 2.5T 3T 3.5T
** A/TDHMD120 5T [5T] 3.5T 4T
HT OFF DELAY HEAT OFF DLY ** Unit specific
100s [100s] 140s 180s 60s A/TUHMB060 960 [960] 1080 830 900
A/TUHMB080 1400 [1400] 1610 1120 1260
FACTORY DEFLTS FACTORY DEFLTS A/TUHMC100 1620 [1620] 1790 1460 1540
NO [NO] YES A/TUHMD120 1890 [1890] 2000 1700 1790
A/TDHMB060 1040 [1040] 1160 900 950
EXIT EXIT A/TDHMB080 1400 [1400] 1610 1300 1350
NO [NO] YES A/TDHMC100 1650 [1650] 1700 1500 1600
A/TDHMD120 1850 [1850] 2040 1660 1760
Information Menu Information Options
MODEL NUMBER MODEL
A/TUHM####
SERIAL NUMBER SERIAL
#####
SW REV NUMBER SW REV NUMBER
#####
SYSTEM STATUS SYSTEM STATUS
OFF
REQUESTED CFM REQUESTED CFM
0 CFM
LAST 4 FAULTS LAST 4 FAULTS
NO ALERTS
INDOOR ALERTS INDOOR ALERTS
NO ALERTS
UNIT TEST UNIT TEST UNIT TEST UNIT TEST
SIMPLE GAS VAL SETUP
TEMP SENSOR TEMP SENSOR
SNSR1 [SNSR1] SNSR2 DLT2-1
UNIT TEST SIMPLE GAS VAL SETUP
MOTOR RPM MOTOR RPM NO [NO] YES MIN [MIN] MAX
0 RPM
INDUCER RPM INDUCER RPM
0 RPM ARE YOU SURE ARE YOU SURE
NO [NO] YES NO [NO] YES
RESET LST FAULT RESET LST FAULT
NO [NO] YES
PART LIST PART LIST
CNT*****
PM SERIAL NUM PM SERIAL NUM
#####
CNTNGNCY MODE CNTNGNCY MODE OR
CNTNGNCY MODE 1
NOT AVAILABLE (with data line connected and active) NO [YES] YES (no data line connected)
EXIT EXIT
NO [NO] YES CNTNGNCY MODE <STAGE> CNTNGNCY MODE <STAGE>
STAGE [OFF] OFF 1 2
DUTY CYCLE [10] 10 20 30 40 50
START [NO] NO YES
NOTES: EXIT [NO] NO YES
1 This menu will only display at comfort control mode when A/TCONT900 is NOT connected
ARE YOU SURE [NO] NO YES
ENTER
2 Shown only when Communicating Outdoor Unit is not detected
ENTER
ENTER
ENTER