TUHM AIRFLOW - HEATING
0.1 0.3 0.5 0.7 0.9
CFM 393 504 512 546 560
Temp. Rise 73 57 56 53 51
Watts 43 81 112 142 140
CFM 435 541 549 580 593
Temp. Rise 66 53 52 50 49
Watts 46 86 119 150 148
CFM 472 573 580 609 621
Temp. Rise 61 50 50 47 46
Watts 50 90 125 159 155
CFM 545 636 644 667 676
Temp. Rise 53 45 45 43 43
Watts 60 103 141 177 169
CFM 565 653 660 682 691
Temp. Rise 68 59 58 57 56
Watts 64 107 145 182 172
CFM 622 703 710 727 734
Temp. Rise 62 55 54 53 53
Watts 75 120 161 199 183
CFM 671 745 752 766 771
Temp. Rise 58 52 51 50 50
Watts 86 133 175 215 192
CFM 769 831 837 843 846
Temp. Rise 50 46 46 46 46
Watts 114 164 210 250 211
CFM 791 849 856 861 862
Temp. Rise 65 61 60 60 60
Watts 121 171 219 258 215
CFM 867 916 922 921 920
Temp. Rise 59 56 56 56 56
Watts 148 201 251 290 230
CFM 932 972 979 973 970
Temp. Rise 55 53 53 53 53
Watts 174 229 282 319 243
CFM 1063 1086 1092 1076 1069
Temp. Rise 48 47 47 48 48
Watts 236 295 353 384 268
100%
(high)
Heat
Low
830
Medium Low
900
Medium**
960
High
1080
65%
(medium)
Heat
Low
623
Medium Low
675
Medium**
720
High
810
Medium Low
504
Medium**
538
High
605
Heating
*UHMB060ACV3VB^ Furnace Heating Airflow (CFM) and Power (watts) vs. External Static Pressure With Filter
Airflow
Setting
Target Airflow
(See Note 5)
External Static Pressure
40%
(low)
Heat
Low
465
0.1 0.3 0.5 0.7 0.9
CFM 512 564 581 538 572
Temp. Rise 70 63 62 66 62
Watts 45 77 112 109 146
CFM 586 634 649 606 634
Temp. Rise 61 56 55 59 56
Watts 57 90 129 127 177
CFM 661 704 717 673 696
Temp. Rise 54 51 50 53 51
Watts 71 106 148 146 207
CFM 772 809 819 774 789
Temp. Rise 46 44 44 46 45
Watts 99 136 184 176 253
CFM 757 794 805 760 776
Temp. Rise 67 63 63 66 65
Watts 95 132 179 172 246
CFM 862 893 901 855 864
Temp. Rise 59 56 56 59 58
Watts 127 165 217 202 289
CFM 967 992 997 951 951
Temp. Rise 52 51 51 53 53
Watts 165 205 262 235 332
CFM 1125 1139 1141 1093 1083
Temp. Rise 45 44 44 46 47
Watts 233 276 341 288 395
CFM 1084 1101 1104 1056 1048
Temp. Rise 65 64 63 66 67
Watts 214 256 319 273 379
CFM 1230 1238 1237 1188 1170
Temp. Rise 57 57 57 59 60
Watts 286 331 401 325 437
CFM 1376 1375 1370 1320 1292
Temp. Rise 51 51 51 53 54
Watts 369 418 495 381 496
CFM 1595 1580 1570 1519 1474
Temp. Rise 44 44 45 46 48
Watts 398 470 522 522 529
Target Airflow
(See Note 5)
40%
(low)
Heat
Low
571
Medium Low
643
Medium**
714
High
821
65%
(medium)
Heat
Low
806
Medium Low
907
Medium**
1008
High
1159
Heating
*UHMB080ACV3VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Airflow
Setting
100%
(high)
Heat
Low
1120
Medium Low
1260
Medium**
1400
High
1610
Notes:
1. * First letter may be "A" or "T".
3. ** Factory setting.
2. ^ Letter may be “A” through “Z”.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected
cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium
heat are percentages of high heat and are not field selectable.

Other manuals for Trane TUHMC100ACV4VB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane TUHMC100ACV4VB and is the answer not in the manual?

Trane TUHMC100ACV4VB Specifications

General IconGeneral
BrandTrane
ModelTUHMC100ACV4VB
CategoryFurnace
LanguageEnglish

Related product manuals