22-1769-07 5
General
Data
Product Specifications
Model No. 1 2TTB3042A1000C 2TTB3048A1000C 2TTB3060A1000C
Electrical Data V/Ph/Hz 2 200/230/1/60 200/230/1/60 208/230/1/60
Min Cir Ampacity 21 25 33
Max Fuse Size (Amps) 35 40 50
Compressor
RECIP
RECIP
SCROLL
RL Amps - LR Amps 15.4 - 93.5 18.6 - 93.4 25.3 - 146
Outdoor Fan FL Amps 1.4 1.4 1.3
Fan HP 1/6 1/6 1/4
Fan Dia (inches) 27.6 27.6 27.6
Coil Spine Fin™ Spine Fin™ Spine Fin™
Refrigerant R-22
(Not factory supplied)
6/13-LB/OZ 8/14-LB/OZ 8/11-LB/OZ
Line Size - (in.) O.D. Gas 3 7/8 1-1/8 1-1/8
Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8
Dimensions H x W x D (Crated) 38.4 x 35.1 x 38.7 46.4 x 35.1 x 38.7 46.4 x 35.1 x 38.7
Weight - Shipping 283 307 280
Weight - Net 249 271 244
Start Components YES YES NO
Sound Enclosure YES NO NO
Compressor Sump Heat NO NO NO
Optional Accessories: 4
Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A
Evaporator Defrost Control A/C AY28X079 AY28X079 AY28X079
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101
Crank Case Heater Kit BAYCCHT300 BAYCCHT300 BAYCCHT300
Hard Start Kit Scroll BAYKSKT263
Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 BAYECMT001
Refrigerant Lineset 5 TAYREFLN3* TAYREFLN4* TAYREFLN4*
AHRI Standard Capacity Rating Conditions
AHRI STANDARD 210/240 RATING CONDITIONS —
(A) Cooling80°FDB,67°FWBairenteringindoorcoil,
95°FDBairenteringoutdoorcoil.
(B) HighTemperatureHeating47°FDB,43°FWBairentering
outdoorcoil,70°FDBairenteringindoorcoil.
(C)LowTemperatureHeating17°FDB,15°FWBairentering
outdoorcoil,70°FDBairenteringindoorcoil.
(D)Ratedindoorairowforheatingisthesameasforcooling.
AHRI STANDARD 270 RATING CONDITIONS —(Noise
ratingnumbersaredeterminedwiththeunitincoolingopera-
tion.)StandardNoiseRatingnumberisat95°Foutdoorair.
Accessory Description and Usage
Anti-Short Cycle Timer—Solidstatetimingdevicethat
preventscompressorrecyclinguntil5minuteshaveelapsed
aftersatisfyingcallorpowerinterruptions.Useinareawith
questionablepowerdelivery,commercialapplications,long
lineset,etc.
Evaporator Defrost Control—SPSTTemperatureactuated
switchthatcyclesthecondenseroffasindoorcoilreaches
freeze-upconditions.Usedforlowambientcoolingto30°F
withTXV.
Rubber Isolators—5largerubberdonutstoisolatecon-
densingunitfromtransmittingenergyintomountingframeor
pad.Useonanyapplicationwheresoundtransmissionneeds
tobeminimized.
Hard Start kit—Startcapacitorandrelaytoassistcompres-
sormotorstartup.Useinareaswithmarginalpowersupply,
onlonglinesets,lowambientconditions,etc.
Extreme Condition Mount Kit—Bracketkitstosecurely
mountcondensingunittoaframeorpadwithoutremoving
anypanels.Useinareaswithhighwinds,oroncommercial
rooftops,etc.