22-1750-05 5
General
Data
SPLIT SYSTEM
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil.
(B) High Temperature Heating 47°F DB, 43°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(D) Rated indoor airflow for heating is the same as for cooling.
ARI STANDARD 270 RATING CONDITIONS — (Noise rating
numbers are determined with the unit in cooling operation.)
Standard Noise Rating number is at 95°F outdoor air.
Accessory Description and Usage
Anti-Short Cycle Timer — Solid state timing device that
prevents compressor recycling until 5 minutes have elapsed
after satisfying call or power interruptions. Use in area with
questionable power delivery, commercial applications, long
lineset, etc.
Evaporator Defrost Control — SPST Temperature actu-
ated switch that cycles the condenser off as indoor coil
reaches freeze-up conditions. Used for low ambient cooling
to 30°F with TXV.
Rubber Isolators — 5 large rubber donuts to isolate
condensing unit from transmitting energy into mounting
frame or pad. Use on any application where sound transmis-
sion needs to be minimized.
Hard Start kit — Start capacitor and relay to assist compressor
motor startup. Use in areas with marginal power supply, on
long linesets, low ambient conditions, etc.
Extreme Condition Mount Kit — Bracket kits to securely
mount condensing unit to a frame or pad without removing any
panels. Use in areas with high winds, or on commercial roof
tops, etc.
Product Specifications
Model No.
1
2TWX4042B1 2TWX4048B1 2TWX4060B1
Electrical Data V/Ph/Hz
2
208/230/1/60 208/230/1/60 208/230/1/60
Min Cir Ampacity 2 4 2 8 3 4
Max Fuse Size (Amps) 4 0 4 5 5 0
Compressor CLIMATUFF
®
- SCROLL CLIMATUFF
®
- SCROLL CLIMATUFF
®
- SCROLL
RL Amps - LR Amps 17.9 - 104 21.2 - 137 25.0 - 148
Outdoor Fan FL Amps 1.30 1.30 2.80
Fan HP 1 / 6 1 / 6 1 / 3
Fan Dia (inches) 27.6 27.6 27.6
Co il Spine Fin™ Spine Fin™ Spine Fin™
Refrigerant R-22 9/10-LB/OZ 10/05-LB/OZ 11/12-LB/OZ
Line Size - (in.) O.D. Gas
3
7/8 1-1/8 1-1/8
Line Size - (in.) O.D. Liquid
3
3/8 3/8 3/8
Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7 53.4 x 35.1 x 38.7 53.4 x 35.1 x 38.7
Weight - Shipping 3 1 0 3 1 4 3 3 9
Weight - Net 2 6 1 2 6 6 2 9 0
Start Components N O N O Y E S
Sound Enclosure Y E S Y E S Y E S
Compressor Sump Heat Y E S Y E S Y E S
Optional Accessories:
4
Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A
Evaporator Defrost Control A/C AY28X084 AY28X084 AY28X084
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101
Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002
Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003
Hard Start Kit Scroll BAYKSKT260 BAYKSKT260
Extreme Condition Mounting Kit B AYECMT004 BAYECMT004 BAYECMT004
Refrigerant Lineset
5
TAYREFLN3* TAYREFLN4* TAYREFLN4*