EasyManuals Logo
Home>Trane>Furnace>XR95

Trane XR95 Performance Data Sheet

Trane XR95
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
22-1836-07 5
Product Specifications 1
MODEL
TYPE
RATINGS
2
Input BTUH
Capacity BTUH (ICS)
3
AFUE (ICS)
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT PIPE DIAMETER — Min (In.)
56
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz
4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
General
Data
TUH1B040A9241A
Upflow / Horizontal
40,000
38,000
95.0
30 - 60
DIRECT
9 x 7
1
4
See Fan Performance Table
1/5
1075
115/1/60
Centrifugal
Direct - 1
1/55 - 3000
115/1/60
1.0
No
High Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
2 — 45
2 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
2
115/1/60
5.2
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
139 / 129
TUH1B060A9361A
Upflow / Horizontal
60,000
57,000
95.0
30 - 60
DIRECT
10 x 7
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/55 - 3450
115/1/60
1.75
No
High Velocity
1 - 17x25 - 1in.
2 Round
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
3
115/1/60
9.2
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
150 / 140
Notes
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet
above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.
6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".
TUH1B080A9421A
Upflow / Horizontal
80,000
76,000
95.0
35 - 65
DIRECT
11 x 8
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/24 - 3450
115/1/60
0.71
No
High Velocity
1 - 17x25 - 1in.
3 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
4
115/1/60
10.2
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
158 / 148

Other manuals for Trane XR95

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane XR95 and is the answer not in the manual?

Trane XR95 Specifications

General IconGeneral
BrandTrane
ModelXR95
CategoryFurnace
LanguageEnglish

Related product manuals