EasyManuals Logo

Troy-Bilt 030240 User Manual

Troy-Bilt 030240
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
TROUBLESHOOTING
Problem Cause Correction
No AC output is available, but
generator is running.
1. One of the circuit breakers is
open.
2. Fault in generator.
3. Poor connection or defective cord
set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact Authorized service facility.
3. Check and repair.
4. Connect another device that is in
good condition.
Generator runs good at no-load
but "bogs" down" when loads are
connected.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. See "Don't Overload Generator".
3. Contact Authorized service facility.
Generator will not start; or starts
and runs rough.
1. Failed battery.
2. Low oil level.
1. Replace battery.
2. Fill crankcase to proper level or
place generator on level surface.
Generator shuts down during
operation.
Out of gasoline. Fill fuel tank.
Generator lacks power. Load is too high. See "Don't Overload Generator".
7
Section
Troubleshooting

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Troy-Bilt 030240 and is the answer not in the manual?

Troy-Bilt 030240 Specifications

General IconGeneral
BrandTroy-Bilt
Model030240
CategoryPortable Generator
LanguageEnglish

Related product manuals