Appendix B
ACGIH
25
Appendix B: Heat Exposure Tables
ACGIH
Screening Criteria for Heat Stress Exposure. WBGT values in C.
NOTE: According to the ACGIH’s guidelines, the temperature values represent a work and
rest process which is explained in the standards. Refer to the ACGIH TLVs and BEIs for
specific details.
Work and recovery
(TLV )
Light
Moderate
Heavy
Very Heavy
75% to 100%
31.0
28.0
26.0*
23.5*
50% to 75%
31.0
29.0
27.5
25.5*
25% to 50%
32.0
30.0
29.0
28.0
0% to 25%
32.5
31.5
30.5
30.0
Work and recovery
(Action Limit )
Light
Moderate
Heavy
Very Heavy
75% to 100%
28.0
25.0
22.5*
20.0*
50% to 75%
28.5
26.0
24.0
22.5*
25% to 50%
29.5
27.0
25.5
24.5
0% to 25%
30.0
29.0
28.0
27.0
*Values not specified by ACGIH have been estimated for continuity.
Appendix B:
Heat Exposure
Tables

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSI Instruments questemp 48n and is the answer not in the manual?

TSI Instruments questemp 48n Specifications

General IconGeneral
BrandTSI Instruments
Modelquestemp 48n
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals