3-33
Section 3 - Service and Repair
This allows calibration of the sensor to cabinet for abnormal
operations. By adjusting this number colder you can change the
average cabinet temperature to a colder value. Not available
on CLR2160.
11. Data download
Along with the separate ESPY software you can download the
rolling data file.
12. Clear error log
Perform this operation after checking the errors.
13. Clear download memory
Clears the rolling data file if desired.
14. Model number displayed
Displays the two-digit model number of the specific unit.
15. Adjust thermistor 1 differential
This number should not be adjusted. Not available on
CLR2160.
16. Adjust thermistor 2 offset
This allows calibration of the sensor to cabinet for abnormal
operations. By adjusting this number colder you can change the
average cabinet temperature to a colder value. Not available
on 2175RF.
17. Adjust thermistor 3 offset
This allows calibration of the sensor to cabinet for abnormal
operations. By adjusting this number colder you can change the
average cabinet temperature to a colder value. Not available
on Rs, WCs or CLR2160.
18. Adjust thermistor 4 offset
This allows calibration of the sensor to cabinet for abnormal
operations. By adjusting this number colder you can change the
average cabinet temperature to a colder value. Not available
on Rs or WCs.
19. Thermistor 2 status
This will show the pure thermistor reading with no offsets
taken into account. When placed in ice water this thermistor
should read 32°F in this menu option. Not available on
2175RF.
20. Thermistor 3 status
This will show the pure thermistor reading with no offsets
taken into account. When placed in ice water this thermistor
should read 32°F in this menu option. Not available on Rs,
WCs or CLR2160.
21. Thermistor 4 status
This will show the pure thermistor reading with no offsets
taken into account. When placed in ice water this thermistor
should read 32°F in this menu option. Not available on Rs,
WCs or CLR2160.
22. Automatic toggle through relays switch on and off
See specific unit section for description.
23. Defrost interval adjust. 3 to 24 hours
This will adjust the interval between defrosts from 3 to 24
hours. Adjusting from the factory settings may cause undesired
temperature in the refrigerator section.
24. Adjust thermistor 2 set-point. Only available on
CO2175F, CO2175DWR, CLR2160 and CLRCO2175.
25. Adjust thermistor 3 set-point. Only available on
2275DWRWS.
26. Adjust thermistor 4 set-point. Only available on
2275DWRWS.
27. Show software revision
This will toggle between main and display board software
revision. The main board number will be accompanied by the
degree symbol.
Error Codes
E1 Thermistor 1 is open. Not available on CLR2160.