ZED-F9K-Integration manual
Figure 17: ZED-F9K example circuit for USB interface
R11 = 100 k Ω is recommended
R4, R5 = 27 Ω is recommended
3.5 Predefined PIOs
In addition to the communication ports, there are some predefined PIOs provided by ZED-F9K to
interact with the receiver. These PIOs are described in this chapter.
If hardware backup mode is used a proper isolation of the interfaces is needed.
3.5.1 D_SEL
The D_SEL pin can be used to configure the functionality of the combined UART1, I2C, and SPI pins.
It is possible to configure the pins as UART1 + I2C, or as SPI. SPI is not available unless D_SEL pin
is set to low. See Table 16 below.
Pin no.
D_SEL == 0 D_SEL == 1
42 SPI_MISO UART1 TXD
43 SPI_MOSI UART1 RXD
44
SPI_CS_N I2C SDA
45 SPI_CLK I2C SCL
Table 16: D_SEL configuration
3.5.2 RESET_N
The ZED-F9K provides the ability to reset the receiver. The RESET_N pin is an input-only pin with an
internal pull-up resistor. Driving RESET_N low for at least 100 ms will trigger a cold start.
The RESET_N pin will delete all information and trigger a cold start. It should only be used
as a recovery option.
3.5.3 SAFEBOOT_N
The ZED-F9K provides a SAFEBOOT_N pin that is used to command the receiver safe boot mode.
If this pin is low at power up, the receiver starts in safe boot mode and GNSS operation is disabled.
The safe boot mode can be used to recover from situations where the flash content has become
corrupted and needs to be restored.
In safe boot mode the receiver runs from a passive oscillator circuit with less accurate timing and
hence the receiver is unable to communicate via USB.
In this mode only UART1 , I2C or SPI communication is possible. For communication via UART1 in
safe boot mode, the host must send a training sequence (0 x 55 55 at 9600 baud) to the receiver in
order to begin communication. After this the host must wait at least 2 ms before sending any data.
UBX-20046189 - R01
3 Receiver functionality Page 41 of 105
C1-Public Early production information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox ZED-F9K and is the answer not in the manual?

Ublox ZED-F9K Specifications

General IconGeneral
BrandUblox
ModelZED-F9K
CategoryControl Unit
LanguageEnglish

Related product manuals