Page #14 background imageLoading...
Page #14 background image
black red
(figure 3)
Warning
To avoid harms to you or damages to the Meter from
electric shock, please do not attempt to measure
voltages higher than 1000V although readings may
be obtained.
The DC Voltage ranges are: 200mV, 2V, 20V, 200V and
1000V.
The AC Voltage ranges are: 2V, 20V, 200V and 750V
Measurement Operation(1)
A.DC and AC Voltage Measurement (see figure 3)
To measure DC or AC Voltage, connect the Meter as follows:
1. Insert the red test lead into the HzV (UT58C)
or
V (UT58A/UT58B) terminal and the black test
lead into the COM input terminal.
2. Set the rotary switch to an appropriate measurement
position in V or V range.
3. Connect the test leads across with the object to be
measured.
The measured value shows on the display.
Model UT58A/B/C: OPERATING MANUAL
14

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT58A and is the answer not in the manual?

UNI-T UT58A Specifications

General IconGeneral
Data holdYes
Product typeDigital multimeter
AC current range0.02 - 20 A
AC voltage range2 - 750 V
DC current range0.002 - 20 A
DC voltage range0.2 - 1000 V
Capacitance range2 - 100000 nF
Basic accuracy (DC current)±(0.8%+1)
Basic accuracy (DC voltage)±(0.5%+1)
Basic accuracy (capacitance)±(4%+3)
Battery voltage9 V
Dimensions (WxDxH)88 x 39 x 179 mm
Weight and Dimensions IconWeight and Dimensions
Weight350 g