14
2.6 - GENERAL FEATURES !DEA Plus
OPERATING DATA ACCORDING TO UNI 10348 !DEA Plus
Attention: should the boilers be used to heat systems at low temperature (e.g. radiant panels), a mixer valve is required to avoid
condensation forming.
!DEA AC 23 Plus CS 24 Plus CS 28 Plus CS 32 Plus
Maximum thermal ow rate kW 25.5 26.5 30.1 34.5
Minimum thermal ow rate kW 11.5 11.5 11.5 13.5
Effective nominal output kW 22.9 24.7 28.1 32.3
Minimum effective output kW 9.9 10.1 10.2 12.2
Effective efciency at nominal load (100%) % 89.8 93.05 93.21 93.5
Effective efciency required (100%) % 89.72 92.78 92.90 93.02
Effective efciency at 30% load % 89.43 90.43 90.42 90.42
Effective efciency required (30%) % 87.08 90.18 90.34 90.53
Number of stars (according to 92/42 EEC) no.
Combustion efciencywithnominalload(100%) % 91.36 93.21 94.6 94.57
Combustion efciency with reduced load % 88.5 88.06 89.52 88.76
Heat loss at casing (min.-max.) % 2.0- 1.6 0.17 - 0.16 0.77-1.40 1.07-1.35
(*) Flue gas temperature tf-ta (max.) % 95.5 119.3 96.3 101.4
Flue gas mass ow rate (min.-max) g/s 19.1-21.2 14.21-13.74 15.17-15.35 18.12-16.8
Excess λ air % 140.7 45.15 42.56 35.34
CO
2
% 2.2-4.6 3.0-7.8 2.8-8.0 2.75-8.4
NOx(WeightedvalueaccordingtoEN297/A3orEN483) mg/kWh 189.2 184.16 186.00 164.05
NOx Class 2 2 2 2
Heat loss at chimneywithburneron(min.-max.) % 8.6-11.5 11.94-6.79 5.40-10.48 5.40-11.2
Heat loss at chimney with burner off % 0.657 0.256 0.321 0.280
Available head at the base of the chimney Min. / Max. Pa 2 / 50 2 / 50 2 / 50 2 / 50
(*) Room Temperature = 20°C
!DEA AC 23 Plus CS 24 Plus CS 28 Plus CS 32 Plus
Appliance category II
2H3P
II
2H3P
II
2H3P
II
2H3P
Minimum heat. circuit output (∆t 20 °C) l/min 7.1 7.2 7.3 8.7
Minimum heating circuit pressure bar 0.5 0.5 0.5 0.5
Maximum heating circuit pressure bar 3 3 3 3
Primary circuit content l 3 3 3.5 3.5
Maximum operating temperature in heat. °C 78 78 78 78
Minimum operating temperature in heat. °C 45 45 45 45
Expansion vessel total capacity l 6 6 8 10
Expansion vessel pre-load bar 1 1 1 1
Maximum system capacity (maxtemp.calc.of82°C) l 138 138 184 230
Minimum domestic hot water circuit ow rate l/min. 2.5 2.5 2.5 2.5
Minimum domestic hot water circuit pressure bar 0.5 0.5 0.5 0.5
Maximum domestic hot water circuit pressure bar 6 6 6 6
Domestic hot water specic ow rate (∆t 30 °C) l/min. 11 12 13.5 15.5
Domestic hot water ow rate limiter l/min. 10 10 12 14
Production of D.H.W. in continuous operation with ∆t 45 K
l/min. 7.8 7.4 8.7 10.3
Production of D.H.W. in continuous operation with ∆t 40 K
l/min. 8.8 8.3 9.8 11.6
Production of D.H.W. in continuous operation with ∆t 35 K
l/min. 10.0 9.5 11.1 13.2
Production of D.H.W. in continuous operation with ∆t 30 K
l/min. 11.7 11.0 13.0 15.4
Production of D.H.W. in continuous operation with ∆t 25 K (*)
l/min. 14.1 13.2 15.6 18.5
Temperature adjustable in domestic hot water mode
°C 35-57 35-57 35-57 35-57
Voltage/Frequency electric power supply V-Hz 230/50 230/50 230/50 230/50
Fuse on the power supply A (F) 2 2 2 2
Maximum absorbed output W 85 138 138 150
Protection rating IP X4D X5D X5D X5D
Net weight kg 28.6 30.1 35.2 36.2
Gross weight kg 31.5 33 38.2 39.2
(*) mixed