14
Installation of this range must conform with local codes, or in the absence
of local codes, with the national Fuel Gas Code ANSIZ223.1 / NFPA 54. In
Canada, installation must conform to the current Natural Gas Installation
code, CAN 1-1.M81 and with local codes where applicable. This range has
been design-certied according to ANSIZ21.1a, latest edition.
MAXIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR LP GAS: 13.0
IN. W.C.
MAXIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR NATURAL
GAS: 10.0 IN. W.C.
OUTLET PRESSURE FOR LPG APPLIANCE REGULATOR IS SET AT 10.0
IN. W.C.
OUTLET PRESSURE FOR NATURAL GAS APPLIANCE REGULATOR IS
SET AT 5.0 IN. W.C.
Keep the area around the installed appliance free of combustible materials,
gasoline and other ammable vapors.
Do not obstruct the ow of combustion air into the range and ventilation air
produced by the range.
It is recommended that the unit be set under a powered, vented exhaust
hood of sufcient size and capacity.
Before installing the range, you must locate and secure the included anti-tip
bracket to your wall for your range.
The use of cabinets for storage above the appliance may result in a potential
burn hazard. Combustible items may ignite, metallic items may become hot
and cause burns. If cabinet storage is in place above the range, the risk or
heat-related damage can be reduced by installing a range hood that projects
horizontally a minimum of 5” (12.7 cm) beyond the bottom of the cabinets.
This appliance shall not be used for space heating. This information is based
on safety considerations. All openings in the wall behind the appliance and in
the oor should be sealed.
GAS SUPPLY REQUIREMENTS