19
Your range must be electrically grounded in accordance with local codes,
or in the absence of local codes, in accordance with the National Electrical
Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must
be in accordance with the current CSA C22.1 Canadian Electrical Code Part
1 and/or local codes. A copy of this standard may be obtained from: National
Fire Protection Association, 1 Battery March Park, Quincy, Massachusettes,
USA, 02269-9101.
The power supply must be the correct polarity. Reverse polarity will result in
continuous sparking of the electrodes, even after the burners have ignited. If
there is any doubt as to whether the power supply has the correct polarity or
grounding, have it checked by a qualited electrician.
Use 120V, 60Hz and a properly grounded branch circuit protect by a 15-amp
or 20-amp circuit breaker or time delay fuse.
ELECTRIC POWER REQUIREMENTS
!
CAUTION
Shortest connection from
hard pipe stub location to
range hookup
This area allows for ush range
installation with through-the-wall
connection of pipe stub/shut-off
valve and rear 120v outlet
This area allows for ush
range installation with
through-the-oor connec-
tion of pipe stub/shut-off
valve