11
ERROR CODE
Error Code
Error type can be read out on the
control display
Err 7
Err 6
Thermostat failure
(If the NTC thermistor is short-
circuit or has no connection).
Err 5
Thermal cut-out of electronic unit
(If the refrigeration system has
been too heavily loaded, or if the
ambient tempreature is high, the
electronic unit will run too hot).
Err 4
Minimum motor speed error
(If the refrigeration system is too
heavily loaded, the motor cannot
maintain minimum speed at ap-
proximately 1,850 rpm).
Err 3
Motor start error
(The rotor is blocked or the dier-
ential pressue in the refrigeration
system is too high(>5bar)).
Err 2
Fan over-current cut-out
(The fan loads the electronic unit
with more than 0.5A).
Err 1
Battery protection cut-out
(The voltage is outside the cut-out
setting).
BLUETOOTH APP
To check the Bluetooth name : Press setting
button one time and see the fridge Bluetooth
name.
Your Bluetooth code is located on the side of
the unit under the power socket.
* To download the APP visit our website at
www.UniqueOgrid.com
LEFT BIN
USB 2.1A
RIGHT BIN
RUN
RUN
COMPRESSOR
BATTERY PROTECTION ON/OFF COOLING SPEED
HIGH
MED
LOW
QUICK
NORM
ECO
NORMAL
USE
EMERGENCY
OVERIDE
DC 12V / 24V
12 / 24V based on input
12 / 24V base sur l’entree

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unique UGP-80L1 W and is the answer not in the manual?

Unique UGP-80L1 W Specifications

General IconGeneral
BrandUnique
ModelUGP-80L1 W
CategoryRefrigerator
LanguageEnglish

Related product manuals