In the front, you use the appropriate auto-drilling
screws ( supplied with the hood ).
Place the appliance respecting the safety standards
in force that you find here following described.
Place the appliance so that its back and lateral sides
can be easily reached in order to make the electrical
connections and provide the needed service.
The appliance is not suitable for built-in installation
The appliance is not suitable for built-in installation
and side by side positioning.
and side by side positioning.
If the appliance is placed near walls, dividers, kitchen
cabinets, decorated edges, etc., it is recommended
that this be of non combustible material.
Otherwise, they must be coated with non combustible
thermal insulating material and you must be very
respectful of the fire prevention standards.
REMOVAL OF THE PROTECTIVE FILM
Carefully remove all the protective film from the
external walls of the appliance. Pay attention not to
leave any rest of glue on the sides. If there should
be any residue, please remove it with an appropriate
The connection to the electrical power supply
system must be done according to the standard
The installer is responsible of the correct electrical
connection and of the compliance of the safety
Before connecting the appliance, make sure that :
the voltage and the frequency correspond to those
stated on the data plate of the appliance.
the outlet has the grounding and that is able to
support the charge requested by the appliance
indicated on its data plate.
the outlet fits the type of the plug installed on the
Avoid to use extensions and multiple outlets.
The appliance must be placed so that the connection
plug can be easily reached.
Place between the appliance and the network
omni-polar switch so that it is easily accessible after
omni-polar switch so that it is easily accessible after
. The contacts of this switch must have
a minimum opening distance of 3 mm and the switch
must have an appropriate input. We advise the use of
magneto-thermal differential switch
magneto-thermal differential switch
When the appliance is working the power supply
voltage must not diverge from the value of the
nominal voltage, written on the technical data plate,
The connection to the electrical power must be done
through a Schuko plug of 16 A.
Place the input cable in a way that no point exceeds
the environment’s temperature for more than 50°C.
connected to the round line
Moreover, the appliance must be
whose efficiency must be properly
checked according to the current
This connection must be done
between the different appliances
using the terminal marked with the symbol:
The equipotential conductor must have a minimum
To connect steam condenser to the oven, please
Remove the back of the oven
Connect the control cable of the hood to the power
board by connecting it to the proper connector (see
Fix the cable fastener your find on the cable of the
hood in the special slit you find on the bottom of the