This manual covers operation of the TM12 Self Propelled Elevating Work Platform.
This manual
must be stored on the machine at all times.
Carefully read, understand and follow all safety rules, operating instructions, labels and the Scaf-
fold Industry Association’s MANUAL OF RESPONSIBILITIES. Perform the following steps each
day before use.
1. Open module covers and inspect for damage, oil leaks or missing parts.
2. Check the level of the hydraulic oil with the platform fully lowered. Open the Chassis Door and
remove the reservoir cap, oil should be visible on the dipstick. Add recommended hydraulic oil
if necessary.
3. Check that fluid level in the batteries is correct (See Battery Maintenance, page 8).
4. Verify that batteries are charged.
5. Check that AC extension cord has been disconnected from chassis outlet.
6. Check that all guardrails are in place with fasteners properly tightened.
7. Inspect the machine thoroughly for cracked welds, loose hardware, hydraulic leaks, damaged
control cable, loose wire connections and wheel bolts.
8. Move machine, if necessary, to unobstructed area to allow for full elevation.
9. Pull Chassis Emergency Stop Switch to the ON position.
10. Pull Platform Emergency Stop Switch to the ON position.
Figure 1:
Chassis Controls
11. Turn and hold the Chassis Key
Switch to CHASSIS. Push the
Chassis Lift/Lower Switch to the
UP position and fully elevate the
platform.
12. Visually inspect the mast assem-
bly for damage or erratic opera-
tion. Check for missing or loose
parts.
13. Verify that the depression mech-
anism supports have fully
rotated into position under the
machine.
14. Turn and hold the Chassis Key
Switch to CHASSIS. Partially
lower the platform by pushing the
Chassis Lift/ Lower Switch to the
DOWN position, and check operation of the audible lowering alarm.
I
NTRODUCTION
P
RE
-O
PERATION
S
AFETY
I
NSPECTION
(F
IGURES
1, 2,
AND
3)
Stop Switch
Hour Meter
Key Switch
Chassis Lift/Lower
Switch
Emergency
Chassis
Chassis

Other manuals for Upright TM12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Upright TM12 and is the answer not in the manual?

Upright TM12 Specifications

General IconGeneral
BrandUpright
ModelTM12
CategoryLifting Systems
LanguageEnglish

Related product manuals