DEEP
WELL INSTALLATION
13.
Thread boiler drain into front of tank tee. Thread
3/4 in. male PVC adapter into inlet side of tank tee.
Connect to household plumbing.
13
PUMP
ELECTRICAL CONNECTIONS
W
ARNING
• Always disconnect pump from electricity before performing any work on the pump.
• Under-sized wiring can cause motor failure and even re. Use proper wire size specied in the Wire
Size Chart.
• Replace damaged or worn wiring cord immediately.
• Do not kink power cable and never allow the cable to come
in contact with oil, grease, hot surfaces, or chemicals.
• The pump must be properly grounded using the proper
wire cable with ground.
• Prevent the power cable from coming in contact with sharp
objects.
• All wiring should be performed by a qualied electrican in
accordance with the National Electric Code and local electric codes.
• Connect the pump to a separate electrical circuit with a dedicated circuit breaker. Refer to the Wire
Size Chart for proper fuse size.
WIRE SIZE CHART
Distance from
Motor to Meter
Recommended
Copper
Wire and Fuse Sizes
Single Phase Motor
115 Volt 230 Volt
0-50 Ft.
50-100 Ft.
100-150 Ft.
150-200 Ft.
200-300 Ft.
12
12
10
8
6
14
14
12
12
10
Fuse Size (Amps) 30 15
CAUTION
Motor Switch Settings
Motors are designed to run on either 115 volt or 230 volt
current. Be sure the motor’s wires are attached properly to
the motor’s control panel for the voltage required.
Conversion Switch
from 115v on 230V
Lowes.com
12
3/4 in. Male
PVC
Adapter
1/2 in. Boiler
Drain
Conversion Switch
from 1
15V to 230V