ENGLISH
8
TECHNICAL DATA
AXIL-230V
AXIL-120V
Opening mechanical stop
Built-in trigger capacitor
AXIL-FC
Opening mechanical stop
Built-in trigger capacitor
Opening electrical limit switch
AXIL-ECD
Opening mechanical stop
Built-in trigger capacitor
Encoder
AXIL-24V
O
pening mechanical stop
Encoder
AXIL-230V AXIL-120V AXIL-24V
Max. leaf lenght m 2,8 2,8 2,8
M
ax. leaf weight
K
g
3
00
3
00
3
00
Power supply Vac - Hz 230 - 50 120 - 60 24 Vdc
Idling current A 0,8 1,7 1,0
F
ull load current
A 1
,1
2
,2
8
Maximum Power W 230 240 200
Capacitor µF 6,3 14 -
Max travel mm 350 350 350
Operating speed m/s 0,016 0,018 0,02 ÷ 0,012
Maximum thrust N 1700 1700 1700
Working temperature °C -30 ÷ +55 -30 ÷ +55 -30 ÷ +55
Protection IP 44 44 44
Working cycle % 35 30 60
Motor weight Kg 7,5 7,5 7,5
INSTALLATION LAYOUT
AXIL actuator
- cable 4 x 0,75 mm
2
(120V/230V)
- cable 3 x 1,5 mm
2
(24V)
Blinker
cable 2 x 1,5 mm
2
Aerial
cable RG-58
Key or digital selector
cable 3 x 0,5 mm
2
Safety edge (EN 12978)
- optical type
- resistive type
Internal photocells
cable 4 x 0,5 mm
2
(RX)
cable 2 x 0,5 mm
2
(TX)
External photocells
cable 4 x 0,5 mm
2
(RX)
cable 2 x 0,5 mm
2
(TX)
Control unit
cable 3 x 1,5 mm
2