T
ABLEAU BRANCHEMENTS ELECTRIQUES
EASY-RM EASY-RI / EASY-CRI
L1 START/UP. Contact N.O.
L2 STOP. Contact N.F.
L3 COMMUN.
L4 DOWN. Contact N.O.
L5 PHOTOCELLULE. Contact N.F.
L6 BARRE PALPEUSE. Contact N.F.
L7 FIRE. Contact N.F.
L8 COMMUN (-)
L9 COMMUN ACCESSOIRES
Seul EASY-CRI
L9
Regulation de la puissance pour BARRE PALPEUSE
OPTIQUE
L10 24VAC ACCESSOIRES (24VDC pour EASY-CRI modèle)
L11
24VAC POUR TEST PHOTO/BARRE PALPEUSE (24VDC
pour EASY-CRI modèle)
E1 - E2
CLIGNOTANT (230VAC / 120VAC) avec intermittence
interne
LUMIÈRE DE COURTOISIE (230VAC / 120VAC)
E3 OUVERTURE MOTEUR
E4 COMMUN 230VAC / 120VAC
E5 FERMETURE MOTEUR
N NEUTRE 230VAC / 120VAC
L PHASE 230VAC / 120VAC
A1 BLINDAGE ANTENNE
A2 CENTRALE ANTENNE
Seul EASY-CRI
IMPORTANT: Les entrées normalement fermées STOP
(L2), PHOTOCELLULE (L5), BARRE PALPEUSE (L6), FIRE (L7), si
elles ne sont pas utilisées doivent être raccordées par
pontage au câble COMMUN (-)
ATTENTION: une mauvaise connexion de l'antenne
compromet sérieusement le fonctionnement RADIO de
l'armoire de commande