19
LED ON OFF
START START input closed START input open
IN2 START P. input closed START P. input open
STOP STOP input closed STOP input open
PHOTO PHOTO input closed PHOTO input open
EDGE
Standard or optical edge
EDGE input closed (edge
not pressed)
EDGE input open (edge
pressed)
Resistive rubber edge
EDGE input closed
(edge pressed)
EDGE input open
(fault)
Edge NO pressed: 8K2
between EDGE input and
common (-)
FCA
Opening limit switch
closed
Opening limit switch open
FCC Closing limit switch closed Closing limit switch open
mains Control unit powered-up
Control unit NOT
powered-up
overload
Accessory power supply
overload
Accessory power supply
within normal operational
limits
L1 Antenna
L2 Antenna shield
L3
Opening command for a standard connection
device with switch normally open.
L4
Pedestrian opening command for a standard
connection device with switch normally open.
L5 STOP command. N.C. switch
L6 Photocell. N.C. switch
L7 Edge. Switch N.C. or resistive rubber edge
L8 Commands common (-) line
L9 - L10
24 VAC power output for photocells and other
accessories
L10 - L11 Power supply for functional test TX photocell
C1 Motor open
C2 Motor common
C3 Motor close
D1 - D2 Courtesy light timer activation switch
D3 - D4 230V - 40W / 120V - 40W blinker
N 230V / 120V power supply - neutral
L 230V / 120V power supply - phase
J1 NOT USED
ADJUSTMENT OF THE POWER
AND OPERATIONAL TIMES
The power and operating times may be adjusted by means of 3
trimmers located on the control unit:
POWER: motor power.
WORK: motor operating time (2 - 120 seconds).
PLEASE NOTE: it is recommended that operating times be
set with the slow down function disabled (DIP 5 OFF).
WARNING: the adjustment of times has to be made
when the gate is still
PAUSE: pause time before automatic re-closure
(2 - 150 seconds).
CONTROL UNIT INDICATORS
(LEDS)
The highlighted boxes indicate the state of the LEDs when the
gate is resting.