37VRT 360 Installation Manual
Start-up 11
Dial Test Test procedure
Turn Circulation
pump
The circulation pump
is activated. All
other elements are
switched off.
Press Display test All display elements
are displayed.
Press Software ver-
sion
The software version
is displayed.
Table 11.2 Service/diagnostic level
Restoring the default settings
• To return the room thermostat to its
default settings, press the P button for
15 seconds.
As soon as the display lights up twice,
the room thermostat has been reset.
This means that you will have to per-
form all individual settings again.
11.3 Handing over to the owner
The owner of the room thermostat must
be instructed about its functions and
how to operate it.
• Hand over any instructions intended
for the owner as well as the room ther-
mostat documents.
• Go through the operating manual with
the owner and answer any questions.
• Draw special attention to the safety
instructions which the owner must fol-
low.
• Tell the owner to keep the instruction
manuals near the room thermostat.