WARNING
This conversion kit shall be installed by
a quali ed service agency in accordance
with the manufacturer’s instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a re, explosion
or production of carbon monoxide
may result causing property damage,
personal injury or loss of life. The
quali ed service agency is responsible
for the proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as speci ed in the
manufacturer’s instructions supplied with
the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
General Notes Regarding Conversion
The conversion may be done before or after the
appliance is installed. However, if the unit has been
installed and wall nish applied, the burner module
must be removed from the replace (see page 3).
Note that the gas must be connected to set the
manifold pressure.
1700KNGK / 1700KPGK Gas Conversion Kit
Use with Valor L2 1700K Heater Models ONLY
INSTALLATION MANUAL
L2 Series
4008081-01
©2019, Miles Industries Ltd.
Kit Contents
1 Pilot injector
1 Main burner injector
1 Minimum rate bypass screw
1 Set of conversion labels
Tools Required
7/16” socket driver with extension to install main
burner injector
Small (jewelers size) at blade screwdriver, to set pres-
sure
• Small at blade screwdriver, to release pressure tap
on valve
Needle nose pliers, to remove bypass screw
Hex (Allen) wrench, 4 mm or 5/32, to remove pilot
injector
Manometer, to set pressure
Wrenches, to disconnect gas line (optional step)
Phillips (+) screwdriver, to remove burner module
(optional step)
1/4” inner diameter tubing
Speci cations
* This appliance is certi ed for use from 04500 feet. For
altitudes above 4500 feet, see local codes.
Model 1700NG 1700LPG
Gas Natural Propane
Altitude (Ft.)* 0-4,500 feet*
Input Maximum (Btu/h) 36,000 36,000
Input Minimum (Btu/h) 21,000 22,500
Manifold Pressure (in w.c.) 4” 10”
Minimum Supply Pressure (in w.c.) 5” 11”
Maximum Supply Pressure (in w.c.) 10” 14”
Main Burner Injector Marking DMS#32 DMS#49
Pilot Injector Marking 51 30
Min. Rate By-Pass Screw
220 160

Other manuals for Valor L2 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Valor L2 SERIES and is the answer not in the manual?

Valor L2 SERIES Specifications

General IconGeneral
BrandValor
ModelL2 SERIES
CategoryFireplace Accessories
LanguageEnglish

Related product manuals