POS App Guide DIM Installation Examples
20
WIRING DIAGRAM FOR AN EXCENTUS CURRENT LOOP INTERFACE
Figure 4. Excentus Current Loop Interface
Console
These cables and terminal
block supplied by Excentus
Dbox
Tank
Monitor
Excentus Interface Box
POS/Controller
VR CAB
(P/N 330591-00X)
Gilbarco
Distribution Box
TLS Console
Connects to CDIM
Set sw
to RUN
CONSOLE
COMM.
PUMP
COMM.
RUN
BYPASS
P/N
S/N
Environmental Products
VEEDER-ROOT
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
VR CDIM
Adaptor Cable
(P/N 330592-XXX)
VR 6-foot, 2-conductor
DIM Assembly Cable
(P/N 331105-001)
WHT +
WHT +
BLK -
+
BLK -
3
2
1
401-9.eps
3 numbered items
contained in V-R kit
(P/N 848702-XXX)