INSTALLATION AND SET-UP INSTRUCTIONS
SURFACE AND PAD REQUIREMENTS
• Your new portable spa must be placed on a uniformly firm,
flat and level surface. A concrete pad 4 inches thick is best.
• In order to prevent flooding of the electrical equipment, the
pad must be such that water will drain away from the spa.
• If your spa is located near sprinklers, adjust or cap them so
as not to hit the siding of the spa.
NOTE: Do not put your spa on any soft surface such as sand, grass,
crushed rock or dirt. Any settling surface will put an uneven pressure and
tension to the spa structure and may void the warranty.
BALCONIES AND DECK REQUIREMENTS
• Decking must be constructed to support 85 pounds per sq. ft.
• Balconies must be constructed to meet current state and
local codes.
• Gates must be self-closing and self-latching.
ELECTRICAL REQUIREMENTS
NOTE: Name badge on rub rail indicates equipment location
15 amp GFCI Rating
Viking 1P 120v, Viking 2P 120v, Aurora P 120v, Aurora P+ 120v,
Royale P 120v, Royale P+ 120v, Regal P 120v, Regal P+ 120v
50 amp GFCI Rating
Viking 3, Aurora 3, Royale, Regal, Royale ETS, Regal ETS, Legacy 1 &
Legend 1
60 amp GFCI Rating
Legacy 2, Legend 2, Heritage 1 & 2, Tradition 1 & 2,
• Your 110-volt or 220-volt spa pack is designed to be
“PERMANENTLY CONNECTED”.
• It is the customer’s responsibility to acquire necessary
permits and to arrange for installation and hook up of
the electrical power.
5