BS 50-4 Maintenance
wc_tx000309gb.fm 29
6. Maintenance
6.1 Periodic Maintenance Schedule
Maintenance, replacement, or repair of the emission control devices and
systems may be performed by any non-road engine repair establishment or
individual.
Daily
before
starting
After
first
5 hours
Every
week
or 25
hours
Every
month
or 100
hours
Every
3 months
or 300
hours
Every
Year
Check fuel level. Check engine oil
level.
Inspect air filter. Replace as
needed.
Check oil level in sightglass.
Check fuel line and fittings for
cracks or leaks. Replace as
needed.
Tighten ramming shoe hardware. 
Check external hardware. 
Clean engine cooling fins.
Clean and check spark plug gap.
Change engine oil.
Replace spark plug.
Clean recoil starter.
Change ramming system oil.*
Inspect crane lifting cable for wear,
damage, or abuse.
Inspect fuel filter.
* Change ramming system oil after first 50 hours of operation.
Note: If engine performance is poor, check, clean, and replace air filter elements as needed.

Other manuals for Wacker Neuson BS 50-4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson BS 50-4 and is the answer not in the manual?

Wacker Neuson BS 50-4 Specifications

General IconGeneral
BrandWacker Neuson
ModelBS 50-4
CategoryPower Tool
LanguageEnglish

Related product manuals