Operation G 2.5A
wc_tx000158gb.fm 22
4.12 To Start
See Graphic: wc_gr000554
4.12.1 Disconnect all loads from the generator.
4.12.2 Open fuel valve by moving lever to the right (a1).
Note: If engine is cold, move choke lever to closed position (b1). If
engine is hot, set choke to open position (b2).
4.12.3 Turn engine switch to "ON" (c1).
4.12.4 Pull starter rope (d).
Note: If the oil level in the engine is low, the engine will not start. If this
happens, check oil level and add oil as needed.
4.12.5 Open choke as engine warms (b2).
4.12.6 Allow engine to warm up a few minutes before attaching loads.
4.12.1
4.13 To Stop
See Graphic: wc_gr000554
4.13.1 Turn off and disconnect all tools and appliances attached to the
generator.
4.13.2 Turn engine switch to “OFF” (c2).
4.13.3 Close fuel valve by moving lever to the left (a2).
Note: To stop engine quickly in an emergency, turn engine switch to
“OFF” (c2).