11
excessive evaporation.
Note: After a power interruption, the machine will restart automatically,
including the cleaning pump if pump switch (E) is in the ON position.
14. When using the machine, it is recommended to lock the front wheels in order
to give it more stability.
RECOMMENDED PREVENTIVE MAINTENANCE
Lift sink (G). A retainer bar at the back will maintain it the open position.
Do not open the sink while heavy objects are placed inside as the weight
may exceed the force of the retainer bar.
1. If unit is to be idle during weekends or for several days, it should be topped
up and the machine must remain ON.
2. If the unit is to be idle for more than one week, it is recommended to turn the
unit off. Before doing so, lift sink (G) and skim off or absorb any accumulation
of oil from the surface of the liquid. The unit should not remain turned off for
more than 4 weeks.
3. If a high concentration of non-digestible contaminants remains in suspension
inside the liquid, turn on the cleaning pump and let the uid circulate for a
couple of hours. The liquid will ow through the lter (H) and the lter bag (M)
which will remove the contaminants.
4. Liquid lter (H) should be inspected periodically. If lter is clogged or very
dirty, (weak or no liquid ow through brush and exible faucet) replace it. The
same process applies for the lter bag (M). This ltering is essential to keep
your liquid clean. See the section “ACCESSORIES” for a listing of available
lter cartridges and lter bags.
5. Ensure that the oat switch oats freely in the liquid.
6. The pH of the cleaning solution should always be between 6 and 9. If the
pH of the solution is outside this range, please contact the BIO-CIRCLE™
technical support line. See page 17 for contact information.
7. Inspect the electrical cord and plug regularly. Replace any damaged parts.
ANNUAL MAINTENANCE
Walter recommends that your MINI 100A be inspected and cleaned annually to
perform at optimal efciency.
Depending on the application, non-digestible matter can accumulate as sludge at
the bottom of the tank over time, which can negatively affect the bioremediation
activity. To facilitate the removal of the sludge, the tank bottom is tapered towards
the drain valve.
- Turn main power switch (I) to “0” and unplug unit.
- Connect a 1 in. hose to the barbed tting of drain valve (K). Fully open the
valve, wait a few seconds and then close the valve. Repeat these steps 3
times to remove most of the sludge.
If the sludge cannot be removed with this method, follow the instructions below: