24 Location of the connections on the machine
Rear view (independent of the pass-through direction)
Screwed cable gland for mains cable
Connection for on-site equipotential bonding system
25 Water connection
The machine and any other relevant additional devices must be connected
by an authorised specialist company in relation to local standards and regu-
lations.
IMPORTANT Observe the connection diagram for detailed information.
Requirements for the on-site inlet water connection
The inlet water must in microbiological aspects have the
quality of drinking water
We recommend a maximum hardness of 3 °dH (3.8 °e /
5.34 °TH / 0.54 mmol/l) in order to prevent scaling in the
machine.
Maximum inlet pressure
(back pressure)
6 - 15 l/min
The flow rate influences the tank filling time.
Requirements for the on-site water supply
easily accessible
not behind the machine
3/4" connector