89005828 13
10 Faults
Fault Cause/Effect Remedy
Appliance does not start up
Customer’s main switch is not
switched on
Switch on customer’s main switch
Stop valve closed Open stop valve
Dishwasher does not fill up
For machines with drain
pump, switch is pressed
and illuminated
Press switch. Indicator lamp must
go out.
Hood is not completely closed
Close hood completely.
Press hood over hood catch
Wash programme does not start
Programme not on standby
Open hood again briefly
until indicator lamp in
programme switch is
extinguished
Too low dosage of detergent or
detergent container empty
Top up detergent container or add
detergent powder
Surface strainer blocked Clean surface strainer
Wash nozzles in the wash arms
blocked
Clean wash nozzles
Items are not clean
Functional fault in the water
treatment
Call Winterhalter customer service
11 Emission values
Noise emission values
Workplace related emission value measured according to DIN EN ISO 11202: L
pAeq