89005828 3
3 Before using the machine
Before you use the machine in your work, it must be connected on your premises by trained specialists in
conformance with locally effective regulations and then set in operation by the Winterhalter customer service.
Do not expose the machine to freezing temperatures. Freezing can damage running water
systems damaged.
3.1 Setup and hookup
Setting up and hooking up the machine to the customer's supply lines and outlets must
be performed in conformance with specific local and national circumstances by ap-
proved fitters.
Completeness check:
After unpacking the machine, first check the delivery against the packing slip to see that it is complete and
has suffered no damage during transportation. Inform the haulage company, the insurance company and the
manufacturer immediately of any damages.
Setting up and aligning the machine
Install supply and drainage tables for pass-through machines and adjust with slight incline to machine or
available sink. Before starting installation, use a spirit level to check that the machine is totally horizontal.
Adjust the machine’s feet to compensate for any unevenness of the floor.
Sanitary installations:
Please observe carefully the information in the attached connection diagram!
Make sure that the water pressure and flow capacity demanded by the connection diagram are
present so that the machine will function properly.
• Install an easily accessible main shutoff valve in the water supply line near the machine. It may not
be located behind the machine.
• The machine is DVGW and WRC approved, or designed and built according to DVGW and WRC gui-
delines. It can be connected to the fresh water supply line without any safety device in between.
• Use the hose and the fine filter in the machine to connect it. The fine filter keeps particles from the
water supply line from getting into the machine and causing extraneous rust to form on the cutlery or
the machine itself.
• If water hardness is greater than 6°d, the installation of a water softener is recommended. Now, the
water inlet temperature is max. 50°C.
• The machine is optionally equipped with a drain pump. The maximum draining capacity is found on
the connection diagram.