Boiler service functions
7
3 Boiler service functions
3.1 Summary
Text display message Display
Range adjustable
from - to Reset Value
0.0 Last fault 00 - FF last fault code can be
deleted
0
0.1 Flow temp. sensor 0 - 99˚C - -
0.2 Hot water temp. sensor 0 - 99˚C - -
0.3 Stor. tank temp.sensor1
(system boiler)
0 - 99˚C - -
0.4 Stor. tank temp.sensor2
(not applicable)
-- -
1.2 Code plug 8714411 XXX 0 - 255 - -
1.4 Voltage at terminal 2
(not applicable)
-- -
1.5 Required flow temp.
(for CH)
0 - 99˚C - -
1.8 Power set by module
(not applicable)
-- -
1.9 Module detection (not applicable) - - -
2.0 Operating mode - normal
Min
Max
normal
2.2 Pump switch mode - 1 - 3 3
2.3 Stor. tank charge outp. - 0 - 100% 100 %
2.4 Anti-cycle mode - 0 - 15 min 3 min
2.5 Max. flow temperature - 35 - 88˚C 88˚C
2.6 Switch.diff.flow temp. - 0 - 30˚C 0,0 K
2.7 Autom. anti-cycle mode
(not applicable)
-on
off
on
2.9 Actual output 0 - 100 % - -
3.0 Fan speed 0 - 255 Hz - -
3.3 Ionisation current no
low
middle
high
--
Table 1