Device
Test
Silence
Function
Test all
interconnected
devices
Initiating device flashes
red. Other
interconnected devices
flash red and green in
sequence, then flash
red.
To test all interconnected
devices, hold down the
Test/Silence button on any
device. The buzzer keeps
beeping until you release the
Test/Silence button.
To test a single device, press
the Test/Silence button.
Test a single
device
Flashes red Two sets of three
long beeps, then
two sets of four
quick beeps .
Silence a smoke
alarm
Flashes red three times
every four seconds.
The silence duration is set for
nine minutes. After that, the
device will alarm again if
smoke concentration reaches
the alarm level.
The silence duration is set for
nine minutes, but the device
will alarm when the CO
concentration reaches the
alarm level after six minutes.
/
/
/ /
Silence a CO
alarm
Exit the
silence
function
Flashes red four times
every 5.8 seconds.
/ The silence duration is set for
10 hours, at which point the
device will exit silence function.
Silence a
low-battery
warning
Flashes yellow once
every 60 seconds.
/Silence an
end-of-life
signal
Flashes yellow three
times every 60 seconds.
The silence duration is set for
22 hours, at which point the
device will exit silence
function.
Flashes green three
times.
Low Battery Warning
Malfunction
End of Life
Flashes yellow once
every 60 seconds.
Replace the battery
immediately.
Beeps once every 60
seconds.
Flashes yellow twice
every 60 seconds.
Flashes yellow three
times every 60 seconds.
Beeps three times
every 60 seconds.
Replace the entire
device immediately.
Clean your device. If the device
still does not function properly,
replace the device immediately.
Beeps twice every 60
seconds.
Technical Specifications
Sensor Type
Product Lifespan
Safety Standards
Smoke Sensitivity
CO Sensitivity
Operating Temperature
Operating Relative Humidity
Alarm Noise Level
Silence Duration
Smoke: Photoelectric
CO: Electrochemical
10 years
UL 217 and UL 2034
Power Supply 120 V AC (60 Hz, 45 mA max, and 9 V Alkaline battery backup)
1.3–3.0% obs/ft
70 ppm for 60–240 minutes
150 ppm for 10–50 minutes
400 ppm for 4–15 minutes
40–100°F (4.4–37.8°C )
10%–85% RH (non-condensing)
≥ 85 dB at 10 feet (3 m) @ 3.2 ± 0.3 kHz pulsing alarm
≤ 9 minutes