Fault
description
Possible reasons
Solution
Unable to turn on
your XPA125
Power cord is not connected Connect power cable correctly
The fuse on the back of the machine
has blown
Replace fuse(30A)
Power cable connection is bad Replace or repair power cord
Power supply connection reversed Return to distributor
Other circumstances Return to distributor
No reception
Antenna is not connected Properly connect the antenna
Antenna failure Replace or repair antenna coax
No communication
Please confirm the propagation
characteristics of the current band
Other circumstances Return to distributor
No trasmission
Antenna is not connected Connect antenna
Inadequate power supply current Replace the power supply
SWR is too high, protection has
been triggered
Start ATU/replace antenna/coax
Incorrect working mode
Select the correct working
mode
Power amplifier unit not enabled Set the PA unit to INUSE
Other circumstances Return to distributor
Antenna tuning
function does not
work
Antenna tuning function is not
enabled
Set the ATU unit to INUSE
Screen has no
display
Power cord is not connected Connect power cable correctly
The fuse on the back of the machine
has been blown off
Replace fuse(30A)
Other circumstances Return to distributor
Smoke comes
from equipment
Replace smoke – Only joking,
return to distributor
4. General troubleshooting
The following are general troubleshooting suggestions. If they do not resolve
the problem the unit will need to be returned to your distributor. Please do
not disassemble the unit as this will invalidate the warranty.