Technical Support US: 888-443-2751 Technical Support INTL: 316-943-2751
18
All values shown on this page are per each oven
OVEN REQUIREMENTS
The HP behind Oven Model stands for High Performance.
NOTE
Inches MM Inches MM
3240 0.170 4.32 0.104 2.64
3240-HP 0.196 4.47 0.125 3.18
3255 0.187 4.75 0.120 3.05
3255-HP 0.209 5.31 0.130 3.30
4455-1B 0.209 5.31 0.130 3.30
4455-1B-HP 0.234 5.94 0.140 3.56
3270-1B 0.196 4.47 0.125 2.82
3270-1B-HP 0.218 4.98 0.134 3.18
Standard (120V/60Hz) - Gas Oven Heating Values & Orifice Sizes
Gas Group I
2H
I
2E
I
2E+
I
2L
I
2ELL
I
3+
I
3B/P (30)
I
3P (30/37/50)
I
3B (37)
Inlet pressure (mbar) 20 20 20/25 25 20/25 28/30/37/50 28-30/37/50 30/37/50 37
Electric Direct Spark Igniter
BSP 3/4" male thread (Both Domestic & World)
Gas Oven Bypass Orifice Sizes
W/C mbar kPa W/C mbar kPa W/C mbar kPa W/C mbar kPa
All 6-14 15-35 1.50-3.50 11.5-14 27.5-35 2.75-3.50 3.5 8.75 0.875 10 25 2.5
Gas Oven Fuel Pressure Requirements
The BTU readings listed are maximums that could be reached while climbing to the set
point temperature. Once set point is reached the BTU/HR will lower. Readings will
vary as oven capacity changes during operation.
NOTE