036-21137-004 Rev. C (0505)
10 Unitary Products Group
COOLING CAPACITY - With Variable Speed Furnaces
UNIT MODEL
VARIABLE SPEED
FURNACE MODEL
COIL MODEL
1
W
COOLING
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
2
EER
TOTAL SENS.
1 PH 12 SEER AC - VARIABLE SPEED
3
H2RC018S06
P1DUA12V/PV8A12****UH G1FA024S14 14 600 19.6 13.4 13.00 12.55
P1DUA12V/PV8A12****UH G2FD024(S,H)14 14 600 20.0 13.6 14.00 12.90
P1XDB12V G2FD024(S,H)17 17 620 20.2 14.0 13.75 12.90
P1XUB12V G1FA024S17 17 620 19.6 13.4 13.00 12.45
P1XUB12V G2FD024(S,H)17 17 620 20.0 13.6 13.75 12.80
H2RC024S06
P1DUA12V/PV8A12****UH G1FA024S14 14 750 23.4 16.8 13.00 11.60
P1DUA12V/PV8A12****UH G2FD024(S,H)14 14 750 24.0 17.3 13.00 12.05
P1XDB12V G2FD024(S,H)17 17 815 24.2 17.5 12.50 11.85
P1XUB12V G1FA024S17 17 730 23.6 17.0 13.00 11.80
P1XUB12V G2FD024(S,H)17 17 730 24.2 17.5 13.00 12.10
H2RC030S06
P1DUA12V/PV8A12****UH G1FA030S14 14 975 29.6 21.1 12.50 11.55
P1DUA12V/PV8A12****UH G2FD035(S,H)14 14 975 30.4 21.7 13.00 11.80
P1DUB16V/PV8B16****UH G1FA036S17 17 1050 30.6 21.9 13.00 11.95
P1DUB16V/PV8B16****UH G2FD030(S,H)17 17 1050 30.6 21.9 13.00 11.95
P1XDB12V G2FD030(S,H)17 17 1050 30.6 21.9 12.50 11.60
P1XUB12V G1FA036S17 17 1020 30.4 21.7 12.75 11.70
P1XUB12V G2FD030(S,H)17 17 1020 30.4 21.7 12.75 11.70
P1XUC16V G1FA036S21 21 1000 30.6 21.9 13.00 12.00
P1XUC16V G2FD036(S,H)21 21 1000 31.4 22.5 13.00 12.30
H2RC036S06
P1DUA12V/PV8A12****UH G1FA036S14 14 1185 33.8 23.6 12.00 10.95
P1DUA12V/PV8A12****UH G2FD035(S,H)14 14 1185 33.2 23.2 11.50 10.80
P1DUB16V G1FA036S17 17 1200 33.4 23.4 12.00 11.15
P1DUB16V G2FD036(S,H)17 17 1200 34.4 24.2 12.25 11.40
P1DUC20V/PV8C20****UH G1FA036S21 21 1200 33.6 23.6 12.00 11.30
P1DUC20V/PV8C20****UH G2FD036(S,H)21 21 1200 34.8 24.4 13.00 11.60
P1XDB12V G2FD036(S,H)17 17 1130 34.4 24.4 12.00 11.15
P1XUB12V G1FA036S17 17 1220 33.2 23.2 11.50 10.80
P1XUB12V G2FD036(S,H)17 17 1200 34.0 23.8 12.00 11.05
P1XUC16V G1FA036S21 21 1200 33.4 23.4 12.00 11.15
P1XUC16V G2FD036(S,H)21 21 1200 34.8 24.4 12.75 11.45
P1XUC20V G1FA048S21 21 1200 34.6 25.8 13.00 11.60
P1XUC20V G2FD042(S,H)21 21 1200 35.2 24.7 13.00 11.65
P1XUD20V G2FD048(S,H)24 24 1260 36.4 25.5 12.75 11.65
H1RC036S(25,46)
P1DUA12V/PV8A12****UH G1FA036S14 14 1185 33.6 25.2 12.00 11.05
P1DUA12V/PV8A12****UH G2FD035(S,H)14 14 1185 33.0 24.5 12.00 10.90
P1DUB16V/PV8B16****UH G1FA036S17 17 1250 33.4 24.8 12.00 11.15
P1DUB16V G2FD036(S,H)17 17 1250 34.0 25.3 12.50 11.30
P1DUC20V/PV8C20****UH G1FA036S21 21 1200 33.6 25.0 12.25 11.45
P1DUC20V/PV8C20****UH G2FD036(S,H)21 21 1200 34.8 25.9 13.00 11.75
P1XUB12V G1FA036S17 17 1220 33.2 24.6 12.00 10.95
P1XUB12V G2FD036(S,H)17 17 1200 34.0 25.3 12.25 11.10
P1XUC16V G1FA036S21 21 1260 33.4 24.8 12.00 11.15
P1XUC16V G2FD036(S,H)21 21 1200 34.8 25.9 12.75 11.60
P1XUC20V G1FA048S21 21 1260 35.6 26.5 13.00 11.50
P1XUC20V G2FD042(S,H)21 21 1260 35.0 26.1 12.75 11.65
P1XUD20V G2FD048(S,H)24 24 1260 35.8 26.6 13.00 11.85
H2RC042S06
P1DUB16V/PV8B16****UH G1FA048S17 17 1400 42.5 30.7 12.50 11.05
P1DUC20V/PV8C20****UH G1FA048S21 21 1400 42.0 30.2 12.50 11.15
P1XDD20V G2FD048(S,H)24 24 1365 43.0 31.1 12.80 11.35
P1XUC16V G1FA048S21 21 1400 42.0 30.2 12.50 11.10
P1XUD20V G1FA060S24 24 1430 43.5 31.2 13.00 11.35
P1XUD20V G2FD048(S,H)24 24 1430 43.0 31.1 12.25 11.05
For Notes See Page 11.